" Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors. "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 171
автори: Earle Abbott Merrill - 1896 - 213 стор.
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...so spliced or jointed as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and...with an insulation equal to that on the conductors. All joints must be soldered, even if made with the Mclntyre or any other patent splicing device. This...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. f. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. /. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. / Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...24« and 40^. *. Tie wires must have an insulation equal to that of the conductors they confine. c. Must be so spliced or joined as to be both mechanically and electricr.lly secure without solder ; they must then be soldered to insure preservation, and the joint...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. f. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Proceedings of the ... Annual Meeting of the Fire Underwriters ..., Випуск 30

Fire Underwriters' Association of the Northwest - 1899 - 220 стор.
...the wires themselves being the only way that a contact was secured. The Code specifies lhat all wires must be so spliced or joined as to be both mechanically...must then be soldered to insure preservation, and the joint covered with an insulation equal to thai on the conductors. Prank No. I2 consists of a burnout...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...Splices or taps in conductors must be avoided as far as possible. Whert it is necessary to make them they must be so spliced or joined as to be both mechanically...electrically secure without solder. They must then U soldered, to insure preservation, covered with an insulating compound equ;u to the insulation of...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 528 стор.
...24 / and 45 b. b. Tie wires must have an insulation equal to that of the conductors they confine. c. Must be so spliced or joined as to be both mechanically...and electrically secure without solder ; they must be (hen soldered to insure preservation, and the joint covered with an insulation equal to that on...
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks for Persons ...

1902 - 742 стор.
...larger wire. b. Tie-wires must have an insulation equal to that of the conductors they confine. c. Must be so spliced or joined as to be both mechanically...must then be soldered to insure preservation, and the joint covered with an insulation equal to that on the conductors. Stranded wires must be soldered...
Повний перегляд - Докладніше про цю книгу