" Must be placed at every point where a change Is made in the size of wire (unless the cut-out In the larger wire will protect the smaller.) (c) Must be in plain sight, or enclosed in an approved cabinet, and readily accessible. "
New Code of Ordinances of the City of New York: Including the Sanitary Code ... - Сторінка 205
автори: New York (N.Y.) - 1922 - 621 стор.
Повний перегляд - Докладніше про цю книгу

Proceedings of the Board of Aldermen of the City of New York, Том 1

New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...coils of the mete\r, such potential coils may be connected on (lie supply side of the service fuses. In risks having private plants, the yard wires running...grounded wire, except as provided in paragraph d of this section. c. Automatic cut-outs must be in plain sight or enclosed in an approved cabinet, and...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1920 - 488 стор.
...above described. Distribution Box} 1 II -• 23&. If/. AUTOMATIC CUT-OUTS (FUSES AND CIRCUIT BREAKERS). Must be placed at every point where a change is made...cut-out in the larger wire will protect the smaller (see No. 18)]. Where the size of wire of a circuit changes, a cut-out should be provided which will protect...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1921 - 536 стор.
...AUTOMATIC CUT-OUTS (FUSES AND CIRCUIT BREAKERS). Must be placed at every point where a change is mafic in the size of wire [unless the cut-out in the larger wire will protect the smaller (see No. 18)]. Where the size of wire of a circuit changes, a cut-out should be provided which will protect...
Повний перегляд - Докладніше про цю книгу

Theoretical and Practical Electrical Engineering: Comprising a Course ..., Том 1

Louis Denton Bliss - 1922 - 796 стор.
...(in possible to the point where they enter the building, and nrrotiKcd to cut off the entire current. Cutouts must be placed at every point where a change is made 6 ;5=^s 15 T; 20 "; 25 .=»: 35 s; 50 55 *t' 70 .* 90 :5 100 I5W 125 JW 150 225 175 275 225 525 in...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1924 - 576 стор.
...outdoor three- wire mains. 8056. GENERAL; FUSES AND CIRCUIT BREAKERS. A fuse or circuit breaker shall be placed at every point where a change is made in the size of wire, unless the fuse or circuit breaker in the larger wire will protect the smaller. X Entrance Entrance FvsiJ-^^ JStvitch...
Повний перегляд - Докладніше про цю книгу

Industrial Electricity, Частина 2

Chester Laurens Dawes - 1925 - 502 стор.
...(see page 244). In order to protect wiring properly, one of these automatic cut-outs must be installed at every point where a change is made in the size of the wire. This does not apply to No. 16 or 18 fixture wire at the outlets, since it would be impracticable...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building; a General ..., Том 4

Various - 2007 - 436 стор.
[ Відображення вмісту сторінки заборонено ]
Попередній перегляд недоступний - Докладніше про цю книгу

Encyclopedia of Engineering: A Treatise on Boilers, Steam Engines ..., Том 3

Calvin Franklin Swingle - 1906 - 488 стор.
...enter at the top, connect to the fuse terminals, current passing through the fuses to the switch. b. Must be placed at every point where a change is made...in the larger wire will protect the smaller, (see No. 61)-l Figure 152, A to D, shows systems of distribution and arrangement of mains in general use....
Повний перегляд - Докладніше про цю книгу

The Electrical Code of the City of New York

New York (N.Y.) - 1913 - 254 стор.
...the next fuse back is small enough to properly protect the wires inside the building in question. b. Must be placed at every point where a change is made...cut-out in the larger wire will protect the smaller (see No. 18)1For three-wire direct current or single phase systems the fuse in the neutral wire, except...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 10

1890 - 768 стор.
...transmit. A cut-out must be placed where the underground or overhead service joins the inside wires, and at every point where a change is made in the size of the wire (unless the cut-out in the larger wire is intended to protect the smaller). The plug or other...
Повний перегляд - Докладніше про цю книгу