Книги Книги 51 - 57 з 57 у Must be placed at every point where a change Is made in the size of wire (unless....
" Must be placed at every point where a change Is made in the size of wire (unless the cut-out In the larger wire will protect the smaller.) (c) Must be in plain sight, or enclosed in an approved cabinet, and readily accessible. "
New Code of Ordinances of the City of New York: Including the Sanitary Code ... - Сторінка 205
автори: New York (N.Y.) - 1922 - 621 стор.
Повний перегляд - Докладніше про цю книгу

Practical Safety Methods and Devices, Manufacturing and Engineering

George Alvin Cowee - 1916 - 434 стор.
...constructed that an arc cannot be maintained across its terminals by the fusing of the metal. Fuses should be placed at every point where a change is made in the size of the wire, unless the one in the larger wire will protect the smaller. Extra fuses should be kept in...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1917 - 426 стор.
...wires from a public service company's mains. 236. If/. AUTOMATIC CUT-OUTS (FUSES AND CIRCUIT BREAKERS). Must be placed at every point where a change is made...cut-out in the larger wire will protect the smaller (see No. 18)]. Where the size of wire of a circuit changes, a cut-out should be provided which will protect...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power as Adopted by the Fire ...

Harry Cooke Cushing (jr.) - 1917 - 360 стор.
...back is small enough to properly protect the wires inside the building in question. Cut-outs should be placed at every point where a change is made in...cutout in the larger wire will protect the smaller (see current carrying capacity of wires page 91)]. Cut-outs should not be placed in any permanently grounded...
Повний перегляд - Докладніше про цю книгу

Carpentry and Contracting: A Practical Reference Work on Carpentry ..., Том 3

1919
...current is a problem for the electrical engineer. The point to be noted here is that fuses or breakers must be placed at every point where a change is made in the size of wire unless the fuse next back will also protect the smaller wire. The rated capacity of fuses must not exceed the...
Повний перегляд - Докладніше про цю книгу

Theoretical and Practical Electrical Engineering: Comprising a Course ..., Том 1

Louis Denton Bliss - 1922
...(in possible to the point where they enter the building, and nrrotiKcd to cut off the entire current. Cutouts must be placed at every point where a change is made 6 ;5=^s 15 T; 20 "; 25 .=»: 35 s; 50 55 *t' 70 .* 90 :5 100 I5W 125 JW 150 225 175 275 225 525 in...
Повний перегляд - Докладніше про цю книгу

Encyclopedia of Engineering: A Treatise on Boilers, Steam Engines ..., Том 3

Calvin Franklin Swingle - 1906
...enter at the top, connect to the fuse terminals, current passing through the fuses to the switch. b. Must be placed at every point where a change is made...in the larger wire will protect the smaller, (see No. 61)-l Figure 152, A to D, shows systems of distribution and arrangement of mains in general use....
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 10

1890
...transmit. A cut-out must be placed where the underground or overhead service joins the inside wires, and at every point where a change is made in the size of the wire (unless the cut-out in the larger wire is intended to protect the smaller). The plug or other...
Повний перегляд - Докладніше про цю книгу