" Must be placed on the switch board, or, if not thereon, at a distance of a foot from combustible material, or separated therefrom by a non-inflammable, non-absorptive, insulating material. "
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... - Сторінка 67
автори: Russell Robb - 1896 - 183 стор.
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - 438 стор.
...also to prevent space being used for storage of rubbish and oily waste. Lightning Arresters should be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.). - 1908 - 1260 стор.
...therefrom by a non-inflammable, non-absorptive insulating material. 2042. 5. Lightning Arresters. — a. Must be attached to each side of every overhead circuit connected with the station. b. Must be located in readily accessible places away from combustible material, and as near as practicable to...
Повний перегляд - Докладніше про цю книгу

Electrical Railroading; Or, Electricity as Applied to Railroad Transportation

Sidney Aylmer-Small - 1908 - 952 стор.
...tested .and approved by the National Board of Fire Underwriters although it has a moving part.] 2. Must be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals...
Повний перегляд - Докладніше про цю книгу

Electrical Railroading; Or, Electricity as Applied to Railroad Transportation

Sidney Aylmer-Small - 1908 - 952 стор.
...tested. and approved by the National Board of Fire Underwriters although it has a moving part.] 2. Must be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals...
Повний перегляд - Докладніше про цю книгу

Elementary Electricity Up-to-date: A Complete, Practical Guide for the ...

Sidney Aylmer-Small - 1909 - 456 стор.
...been tested and approved by the National Board of Fire Underwriters although it has a moving part.] 2. Must be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals...
Повний перегляд - Докладніше про цю книгу

Elementary Electricity Up-to-date: A Complete, Practical Guide for the ...

Sidney Aylmer-Small - 1918 - 892 стор.
...been tested and approved by the National Board of Fire Underwriters although it has a moving part.] 2. Must be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals...