" Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and... "
New Catechism of Electricity: A Practical Treatise - Сторінка 404
автори: Nehemiah Hawkins - 1896 - 541 стор.
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...adjacent combustible material. Special attention is called to the fact that switchboards should riot be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Minutes of Proceedings of the Institution of Civil Engineers, Том 143

Institution of Civil Engineers (Great Britain) - 1901 - 510 стор.
...from generators to switchboards must be readily accessible. Bus bars may be made of bare metal. '• Switchboards should not be built down to the floor, nor up to the ceiling; must be made of incombustible insulating material ; and must be accessible from all sides when the...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - 204 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Practical Lessons in Electricity. Elements of Electricity. The Electric Current

American School (Lansing, Ill.) - 1903 - 320 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: Current measurements; Wiring; Telegraph

1905 - 484 стор.
...A slate slab is preferable. Special attention is called to the fact that switchboards should not bo built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Modern Shop Practice: A Manual of Shop Practice ..., Том 3

Howard Monroe Raymond - 1906 - 662 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906 - 528 стор.
...slate slab is preferable. Special attention is called to the fact that switchboards should not 157 be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and tho board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

1906 - 590 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards should not be "-iiZ* i .-*-=. - ; -~zf: i>:r. z»:c ^p » tie ctCisg, bat a space of at -.tz. .r Tv-l-* iir^ies *i»;di...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - 438 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...switchboard Is of concrete or other fireproof construction, and a spare of three feet, If possible, between the ceiling and the board, In order to prevent fire from communicating from tlio switchboard to the floor or ceiling, and also to prevent the farming of a partially concealed...
Повний перегляд - Докладніше про цю книгу