" Underground Conductors. a. Must be protected against moisture and mechanical injury where brought into a building, and all combustible material must be kept from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 170
автори: Earle Abbott Merrill - 1896 - 213 стор.
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...mechanical injury, and, all combustible material must be kept removed from the immediate vicinity. It. Must not be so arranged as to shunt the current through a building around any catch-box. Hi. Table Carrying: Capacity of Wire*. Below is a table which must be followed in placing interior...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 528 стор.
...mechanical injury, and all combustible material must be kept removed from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch-box. 16. Table Carrying Capacity of Wires — Below is a table which must be followed in placing interior...
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks for ..., Том 13

1902 - 738 стор.
...mechanical injury, and all combustible material must be kept removed from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch box. This refers to catch boxes in the street, from which the wires should run to the buildings,...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring

1906 - 544 стор.
...mechanical injury, and all combustible material must be kept removed from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch box. This refers to catch boxes in the street, from which the wires should run to the buildings,...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.). - 1908 - 1260 стор.
...mechanical injury, and all combustible material must be kept removed from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch-box. 2051. 14. Table of Carrying Capacity of Wires.— The following table must be followed in placing interior...
Повний перегляд - Докладніше про цю книгу

Storage batteries ; incandescent lighting ; arc lighting ; interior wiring ...

International Correspondence Schools - 1908 - 754 стор.
...mechanical injury, and all combustible material must be kept removed from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch box. This refers to catch boxes in the street, from which the wires should run to the buildings,...
Повний перегляд - Докладніше про цю книгу

Ordinances Relating to Buildings, City of Seattle

1910 - 232 стор.
...mechanical injury where brought into a building, and must be kept free from all combustible materials: must not be so arranged as to shunt the current through a building around any catch box; and where underground service enters building through tubes, the tubes must be tightly closed...
Повний перегляд - Докладніше про цю книгу

The Electrical Code ...: Comprising the Rules and Regulations for the ...

1913 - 242 стор.
...brought into a building, and all combustible material must be kept from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch-box. c. Where underground service enters building through tubes, the tubes shall be tightly closed at outlets...
Повний перегляд - Докладніше про цю книгу

Electric Wiring

Joseph Gerald Branch - 1913 - 316 стор.
...brought into a building, and all combustible material must be kept from the immediate vicinity. b. Must not be so arranged as to shunt the current through a building around any catch-box. C. Where Tmderground service enters building through tubes, the tubes shall be tightly closed at outlets...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 332 стор.
...into a building, and all combustible material should be kept from the immediate vicinity. They should not be so arranged as to shunt the current through a building around any catch-box. Where underground service enters building through tubes, the tubes shall be tightly closed at outlets...