" at every point where a change is made in the size of the wire (unless the cut-out in the larger wire is intended to protect the smaller). "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 164
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Fire Prevention and Insurance: A General Reference Work ..., Том 3

1912 - 556 стор.
...problem for the electrical engineer. The point to be noted here is that fuses or breakers must be placed at every point where a change is made in the size of wire unless the fuse next back will also protect the smaller wire. The rated capacity of fuses must...
Повний перегляд - Докладніше про цю книгу

The Electrical Code ...: Comprising the Rules and Regulations for the ...

1913 - 242 стор.
...back is small enough to properly protect the wires inside the building in question. b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller (see No. 18)123.Automatic Cut-outs...
Повний перегляд - Докладніше про цю книгу

Electric Wiring

Joseph Gerald Branch - 1913 - 316 стор.
...back is small enough to properly protect the wires inside the building in question. b. Must be placed at every point where a change is made in the size of wire (unless the cut-out in the larger wire will protect the smaller). c. Must be in plain sight, or...
Повний перегляд - Докладніше про цю книгу

Building, Plumbing, Gas and Electrical Laws of the City of Dallas, Texas ...

Dallas (Tex.). - 1914 - 266 стор.
...circuits entering other buildings need not ordinarily be protected by entrance fuses. (e) Must be placed at every point where a change is made in the size of wire, unless the cut-out in the large wire will protect the smaller. (f ) No main or branch fuse block...
Повний перегляд - Докладніше про цю книгу

Practical Safety Methods and Devices, Manufacturing and Engineering

George Alvin Cowee - 1916 - 468 стор.
...an arc cannot be maintained across its terminals by the fusing of the metal. Fuses should be placed at every point where a change is made in the size of the wire, unless the one in the larger wire will protect the smaller. Extra fuses should be kept in a handy place where...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1916 - 458 стор.
...Cut-Outs. (For construction rules, see No. 67.) a. Must be placed at every point where a change is made n the size of the wire (unless the cut-out in the larger wire vili protect the smaller). b. In such places as upper decks, holds, cargo spaces and ire-rooms, a water-tight...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: A General Reference Work on Direct ..., Том 1

1916 - 1028 стор.
...problem for the electrical engineer. The point to be noted here is that fuses or breakers must be placed at every point where a change is made in the size of wire unless the fuse next back will also protect the smaller wire. The rated capacity of fuses must...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry, and Building: A General ..., Том 9

1917 - 546 стор.
...problem for the electrical engineer. The point to be noted here is that fuses or breakers must be placed at every point where a change is made in the size of wire unless the fuse next back will also protect the smaller wire. The rated capacity of fuseis must...
Повний перегляд - Докладніше про цю книгу

Carpentry and Contracting: A Practical Reference Work on Carpentry ..., Том 3

1919 - 444 стор.
...problem for the electrical engineer. The point to be noted here is that fuses or breakers must be placed at every point where a change is made in the size of wire unless the fuse next back will also protect the smaller wire. The rated capacity of fuses must...
Повний перегляд - Докладніше про цю книгу

Proceedings of the Board of Aldermen of the City of New York, Том 1

New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...to properly protect the wires inside the building in question. b. Automatic cut-outs must be placed at every point where a change is made in the size of wire, unless the cut-out in the larger wire will protect the smaller (see §418 of this chapter). This...