" No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing, will be approved. h. Each fixture must be tested for "contacts... "
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... - Сторінка 140
автори: Russell Robb - 1896 - 183 стор.
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...BWG, No. 2 ESG e. All burs or fins must be removed before the conductors are drawn into a fixture. f. The tendency to condensation within the pipes should...conductors and fixtures, for "short circuits," and for ground connections before the fixture is connected to its supply conductors. /'. Ceiling blocks of...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...abraded, and must not in any case be smaller than No. 18 B. & S., No. 2o BWG , No. 2 ESG e. All burs or fins must be removed before the conductors are...than one-fourth inch between the inside pipe and the outsike casing will be approved. h. Each fixture must be tested for " contacts " between conductors...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 708 стор.
...ceiling. b. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. "if. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...ceiling. t>. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 514 стор.
...condensation within the pipes should be guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are...inside pipe and the outside casing will be approved. c. Must be tested for "contacts" between conductors and fixture, for "short circuits," and for ground...
Повний перегляд - Докладніше про цю книгу

Electric Lighting: A Practical Exposition of the Art, for the Use of ..., Том 2

Francis Bacon Crocker - 1901 - 528 стор.
...ceiling. b. Must have all burs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...celling. b. Must have all burs, or fins, removed before the conductois are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than one-fourth inch...
Повний перегляд - Докладніше про цю книгу

Agents' and Inspectators Pocket-book of Fire Protection

George Velten Steeb - 1902 - 230 стор.
...must be so secured as not to be abraded by the pressure of the fastenings or motion of the fixture. No combination fixture in which the conductors are...inside pipe and the outside casing will be approved, and under no circumstances shall there be a difference of potential of more than 300 volts between...
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks for Persons ...

1902 - 742 стор.
...ceiling. b. Must have all burrs, or fins, removed before the conductors are drawn into the fixture. c. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. d. No combination fixture in which the conductors are concealed in a space less than ± inch between...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - 204 стор.
...porcelain tubes. All burs or fins should be removed from the fixtures before the wires are drawn in. The tendency to condensation within the pipes should...guarded against by sealing the upper end of the fixture. In combination fixtures, where the wiring is concealed between the inside pipe and outer casing, the...