Сховані поля
Книги Книги
" The switch must be so constructed that it shall be automatic in its action, not stopping between points when started, and prevent an arc between the points under all circumstances ; it must indicate on inspection whether the current be " on " or  "
Electrical Engineer - Сторінка 200
1894
Повний перегляд - Докладніше про цю книгу

The Electrical Code ...: Comprising the Rules and Regulations for the ...

1913 - 242 стор.
...the building through an approved double-contact service switch, mounted in a non-combustible case, kept free from moisture, and easy of access to police or firemen. o. Must always be in plain sight, and never encased, except when required by the Inspection Department...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1917 - 446 стор.
...leave the building through an approved double-contact service switch, mounted in a noncombustible case, kept free from moisture, and easy of access to police or firemen. To cut a series lighting device out of circuit, a shunt is arranged around the device. For example,...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1920 - 488 стор.
...leave the building through an approved double-contact service switch, mounted in a noncombustible case, kept free from moisture, and easy of access to police or firemen. • To cut a series lighting device out of circuit, a shunt is arranged around the device. For example,...
Повний перегляд - Докладніше про цю книгу

Encyclopedia of Engineering: A Treatise on Boilers, Steam Engines ..., Том 3

Calvin Franklin Swingle - 1906 - 488 стор.
...through an approved double-contact service switch (see No. 51 b), mounted in a non-combustible case, kept free from moisture, and easy of access to police or firemen. FIGURE 147. In order that all of the wiring in the building may be entirely disconnected a switch,...
Повний перегляд - Докладніше про цю книгу

The Electrical Code of the City of New York

New York (N.Y.) - 1913 - 254 стор.
...the building through an approved double-contact service switch, mounted in a non-combustible case, kept free from moisture, and easy of access to police or firemen. o. Must always be in plain sight, and never •encased, except when required by the Inspection Department...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF