" The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables. "
Electric Lighting: A Practical Exposition of the Art, for the Use of ... - Сторінка 460
автори: Francis Bacon Crocker - 1901
Повний перегляд - Докладніше про цю книгу

Medical Electricity, Röntgen Rays and Radium: With a Practical Chapter on ...

Sinclair Tousey - 1915 - 1418 стор.
...66,370 1 107 156 83,690 0 127 185 105,500 00 150 220 133,100 000 177 262 167,800 0000 210 312 211,600 The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the insulating property by the heat of the wires, not from fear of igniting the insulation. The question...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 332 стор.
....0058 .0055 .0052 .0050 4968 5278 5588 5898 6208 o ttH The lower current carrying limit (fifth column) is specified for rubber-covered wires to prevent gradual deterioration of the high The strength of soft copper wire varies from 32,000 to 36,000 pounds per square inch, and of hard copper...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: A General Reference Work on Direct ..., Том 3

1916 - 984 стор.
...Board of Fire Underwriters are given in Table II. TABLE II Safe-Carrying Capacities of Copper Wires The lower limit is specified for rubber-covered wires...taken into consideration in the above tables. The safe-carrying capacity of insulated aluminum wire is 84 per cent of that given for copper wires of...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1916 - 456 стор.
...,600.000 890 1,430 1,700.000 930 1,490 1,800,000 970 1,550 1,900,000 1,010 1,610 2,000,000 1,050 1,670 The lower limit is specified for rubber-covered wires...not taken into consideration in the above tables. WIRING TABLES. The wiring tables, II-VI, are arranged in the following manner : For each size of wire...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1916 - 458 стор.
...1,700.000 030 1,490 1,800.000 970 1,550 1.noo.ooo 1.010 1.o10 2,000,000 1,050 1,670 The lower limit la specified for rubber-covered wires to prevent gradual...deterioration of the high insulations by the heat of the wlrrn. hut not from fear of igniting the insulation. The question of drop to not taken into consideration...
Повний перегляд - Докладніше про цю книгу

Hawkins Electrical Guide ...: Questions, Answers & Illustrations ..., Випуск 3

Nehemiah Hawkins - 1917 - 328 стор.
...1,360 1,430 1,490 1,550 1,610 1,670 HAWKINS ELECTRICITY The lower limit is specified for rubber covered wires to prevent gradual deterioration of the high...question of drop is not taken into consideration in the table on page 731. The carrying capacity of Nos. 16 and 18 B. & S. gauge wire is given, but no smaller...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power as Adopted by the Fire ...

Harry Cooke Cushing - 1917 - 374 стор.
...dimensions of bare and insulated wires, see Index. The lower current carrying limit (fifth column) is specified for rubber-covered wires to prevent gradual...but not from fear of igniting the insulation. The carrying capacity of Nos. 18 and 16 B. & S. gauge wire is given, but no smaller than No. 14 should...
Повний перегляд - Докладніше про цю книгу

Instruction of Disabled Men in Motion Picture Projection: An Elementary Text ...

James Ross Cameron - 1918 - 156 стор.
...looking over to the first column we find this to be a No. 6 wire. CARRYING CAPACITY OF COPPER WIRK The lower limit is specified for rubber-covered wires...not taken into consideration in the above tables. Table A Rubber Insulation Ampere Table B Other Insulations Ampere B. & S. Gauge Circular Mile IS 1,62)...
Повний перегляд - Докладніше про цю книгу

Labor Laws of the State of Wisconsin and Orders of the Industrial Commission ...

Wisconsin - 1920 - 354 стор.
...Covered Wires Table B -Weatherproof Wires CIRCULAR MILLS The lower limit is specified for rubber covered wires to prevent gradual deterioration of the high...the insulation. The question of drop is not taken in consideration in the above tables. Penalty for violations. Section 1636 — 17. Any violation of...
Повний перегляд - Докладніше про цю книгу

Motion Picture Projection: An Elementary Text-book

James Ross Cameron - 1921 - 568 стор.
...table and we find it is 26,250, and looking over to the first column we find this to be a No. 6 wire. The lower limit is specified for rubber-covered wires...not taken into consideration in the above tables. CARRYING CAPACITY OF COPPER WIRE Table A Table B B. & S. Gauge Circular Mils Rubber Insulat. Other...
Повний перегляд - Докладніше про цю книгу