Книги Книги 21 - 30 з 41 у Must be so placed in wet places that an air space will be left between conductors....
" Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under,... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 128
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring

1906 - 550 стор.
...be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over, rather than under, pipes on which moisture is likely to gather or which, by leaking, might cause trouble...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906
...places it should be arranged so that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over rather than under pipes upon which moisture is likely to gather, or which by leaking might cause trouble...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

Louis Derr - 1906
...places it should bo arranged so that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over rather than under pipes upon which moisture is likely to gather, or which by leaking might cause trouble...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of architecture, carpentry, and building: a general reference ...

American School (Lansing, Ill.) - 1907
...places it should be arranged so that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over rather than under pipes upon which moisture is likely to gather, or which by leaking might cause trouble...
Повний перегляд - Докладніше про цю книгу

Modern electrical construction...

Henry Charles Horstmann, Victor Hugo Tousley - 1908
...be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over rather than under pipes upon which moisture is likely to gather or which, by leaking, might cause trouble...
Повний перегляд - Докладніше про цю книгу

Storage batteries ; Incandescent lighting ; Arc lighting ; Interior wiring ...

International Correspondence Schools - 1908 - 639 стор.
...be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over, rather than under, pipes on which moisture is likely to gather or which, by leaking, might cause trouble...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.)., James C. Michael, Hiram David Frankel - 1908 - 1245 стор.
...be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...cannot come in contact with the pipe accidentally. Wire should be run over, rather than under, pipes upon which moisture is likely to gather, or which...
Повний перегляд - Докладніше про цю книгу

Medical Electricity Röntgen Rays and Radium: With a Practical Chapter on ...

Sinclair Tousey - 1915 - 1219 стор.
...be so placed in wet places that an air-space will be left between conductors and pipes in crossing, and the former must be run in such a way that they...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 224 стор.
...arranged so that an air space will be left between conductors and pipes in crossing, and the former should be run in such a way that they cannot come in contact with the pipe accidentally. Where one wire crosses another wire the best and usual means of separating them is by a porcelain tube...
Повний перегляд - Докладніше про цю книгу

Digest of the City of Little Rock, Arkansas

Little Rock (Ark.). - 1915 - 459 стор.
...be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they can not cotne in contact with the pipe accidentally. Wires should be run over, rather than under, pipes...
Повний перегляд - Докладніше про цю книгу