Сховані поля
Книги Книги
" Service blocks must be covered over their entire surface with at least two coats of waterproof paint. c. Must be at least seven feet above the highest point of flat roofs, and at least one foot above the ridge of pitched roofs over which they pass or... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 121
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...proper insulating supports. 4. At least 7ft. above the highest point of flat roofs, and at least 1ft. above the ridge of pitched roofs, over which they...are attached. 5. Protected whenever necessary, in view of possible accidents to conductors or supports, from possibility of contact with other conducting...
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...equal to that of the conductors they confine. 3. So placed that moisture cannot form a cross-connection between them ; not less than a foot apart and not...are attached. 5. Protected whenever necessary, in view of possible accidents to conductors or supports, from possibility of contact with other conducting...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...foot apart, and not in contact with any substance other than their insulating supports. (e) Must be at least seven feet above the highest point of flat...over which they pass or to which they are attached. (d) Must bo protected by dead insulated guard irons or irirt& from possibility of contact with other...
Повний перегляд - Докладніше про цю книгу

A Hand-book of Wiring Tables for Arc, Incandescent Lighting, and Motor Circuits

Arthur Eugene Watson - 1892 - 118 стор.
...their proper insulating supports. 5. Conducting wires carried over or attached to buildings, must be at least seven feet above the highest point of flat roofs, and one foot above the ridge of pitch roofs. Lines constructed subsequent to the adoption of these regulations...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...foot apart, and not in contact with any substance other than their insulating supports. c. Must be at least seven feet above the highest point of flat...over which they pass or to which they are attached. d. Must be protected by dead insulated guard irons or wires from possibility of contact with other...
Повний перегляд - Докладніше про цю книгу

Practical Dynamo Building: With Detail Drawings and Instructions for Winding

La Motte C. Atwood - 1893 - 180 стор.
...their proper insulating supports. 5. Conducting wires carried over or attached to buildings, must be at least seven feet above the highest point of flat roofs, and one foot above the ridge of pitch roofs. Lines constructed subsequent to the adoption of these regulations...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...foot apart and not In contact with any substance other than proper insulating supporta. 4. Must be at least seven feet above the highest point of flat...which they pass or to which they are attached. 5. Must be protected, whenever necessary, In view of possible accidents to conductors or supporta, from...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...EXCHANGE. 161. Outside Wires. — Conducting wires carried over or attached to buildings must be (a) at least seven feet above the highest point of flat roofs, and (6) one foot above the ridge of " pitched :' roofs : (£) when in proximity to other conductors likely...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...foot apart, and not in contact with any substance other than their insulating supports. c. Must be at least seven feet above the highest point of flat...over which they pass or to which they are attached, d Must be protected by dead insulated guard irons or wires from possibility of contact with other conducting...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...wires having an insulation equal to that of the conductors they confine. (See Definitions). c. Must be at least seven feet above the highest point of flat...over which they pass or to which they are attached. d. Must be protected by dead insulated guard irons or wires from possibility of contact with other...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF