| Walter Benedict Weber - 1916 - 164 стор.
...covered with an insulation equal to that on the conductors. Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and, whether stranded or solid, when they have a conductivity greater than that of No. 8 B & S gauge, they... | |
| Terrell Croft - 1917 - 446 стор.
...relating to the splicing of conductors. 16 c. If//. WIRES. Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S. gage they... | |
| Terrell Croft - 1920 - 488 стор.
...relating to the splicing of conductors. 16c. 'ill. WIRES. Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S. gage they... | |
| New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...covered with an insulation equal to that on the conductors. Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S. gauge they... | |
| Sinclair Tousey - 1921 - 1372 стор.
...be soldered to insure preservation and covered with an insulation equal to that on the conductors. Stranded wires must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B & S. guage, they... | |
| New York (N.Y.) - 1922 - 636 стор.
...covered with an insulation equal to that on the conductors. Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S. gage they... | |
| Calvin Franklin Swingle - 1906 - 488 стор.
...be soldered to insure preservation and covered with an insulation equal to that on the conductors. Stranded wires must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S. Gauge they... | |
| New York (N.Y.) - 1913 - 254 стор.
...covered with an insulation equal to that on the conductors. Stranded wires (except in flexible cords) must be soldered before being fastened under clamps or binding screws, and whether stranded or solid, when they have a conductivity greater than that of No. 8 B. & S. gage they... | |
| |