" ... except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished... "
Agents' and Inspectators Pocket-book of Fire Protection - Сторінка 82
автори: George Velten Steeb - 1902 - 218 стор.
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A General Reference Work on Steam Boilers ..., Том 7

Louis Derr - 1910 - 524 стор.
...impossible and impracticable to employ knobs and tubes, provided the difference in potential between the wires is not over 300 volts, and if the wires are not subFig. 17. Flexible Tubing, "Flexduct" Type. Courtesy of National Metal Molding Co., Pittiburg, Pa....
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: A General Reference Work on Direct ..., Том 1

1913 - 460 стор.
...approved metal conduit, or approved armored cable, except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу

Building, Plumbing, Gas and Electrical Laws of the City of Dallas, Texas ...

Dallas (Tex.). - 1914 - 266 стор.
...Section 12), except that if the difference of potential between the wires is not over three hundred (300) volts, and if the wires are not exposed to moisture, they may be finished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 332 стор.
...approved metal conduit, or approved armored cable except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу

Digest of the City of Little Rock, Arkansas

Little Rock (Ark.). - 1915 - 770 стор.
...approved metal conduit, or approved armored cable, except that if the difference of potential between the wires is not over 300 volts, and if the wires, are not exposed to moisture, they may be fixed if separately encased in approved flexible tubing extending in continues lengths from porcelain...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1917 - 446 стор.
...approved metal conduit, or approved armored cable, except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power as Adopted by the Fire ...

Harry Cooke Cushing - 1917 - 374 стор.
...conduit, or approved armored cable (see p. 135) except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу

Carpentry and Contracting: A Practical Reference Work on Carpentry ..., Том 3

1919 - 444 стор.
...approved metal conduit, or approved armored cable, except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1920 - 488 стор.
...approved metal conduit, or approved armored cable, except that if the difference of potential between the wires is not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу

The Electrical Code of the City of New York

New York (N.Y.) - 1913 - 254 стор.
...armored cable, except that if the difference of potential between the wires is 26. Wires — Continued. not over 300 volts, and if the wires are not exposed to moisture, they may be fished if separately encased in approved flexible tubing, extending in continuous lengths from porcelain support...
Повний перегляд - Докладніше про цю книгу