" Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches... "
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... - Сторінка 64
автори: Russell Robb - 1896 - 183 стор.
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: Current measurements; Wiring; Telegraph

1905 - 484 стор.
...A slate slab is preferable. Special attention is called to the fact that switchboards should not bo built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Modern Shop Practice: A Manual of Shop Practice ..., Том 3

Howard Monroe Raymond - 1906 - 662 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906 - 528 стор.
...slate slab is preferable. Special attention is called to the fact that switchboards should not 157 be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and tho board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

1906 - 590 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards should not be "-iiZ* i .-*-=. - ; -~zf: i>:r. z»:c ^p » tie ctCisg, bat a space of at -.tz. .r Tv-l-* iir^ies *i»;di...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - 438 стор.
...separated therefrom by a non-inflammable, non-absorptive insulating material. A slate slab is preferable. Special attention is called to the fact that switchboards...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...switchboard Is of concrete or other fireproof construction, and a spare of three feet, If possible, between the ceiling and the board, In order to prevent fire from communicating from tlio switchboard to the floor or ceiling, and also to prevent the farming of a partially concealed...
Повний перегляд - Докладніше про цю книгу

Building, Plumbing, Gas and Electrical Laws of the City of Dallas, Texas ...

Dallas (Tex.). - 1914 - 266 стор.
...in localities other than engine rooms, for in engine rooms they would be under expert supervision. Special attention is called to the fact that switchboards...be built down to the floor, nor up to the ceiling. A space of at least ten or twelve (10 or 12) inches should be left between the floor and the board,...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 332 стор.
...mechanical injury or moisture, be run in approved conduit or equivalent. Special attention is again called to the fact that switchboards should not be...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and thirty-six inches between...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power as Adopted by the Fire ...

Harry Cooke Cushing - 1917 - 374 стор.
...flexible tubing to extend at least i inch beyond the ends of the conduit. Special attention is again called to the fact that switchboards should not be...floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and thirty-six inches between...
Повний перегляд - Докладніше про цю книгу

Encyclopedia of Engineering: A Treatise on Boilers, Steam Engines ..., Том 3

Calvin Franklin Swingle - 1906 - 488 стор.
...placed as to reduce to a minimum the danger of communicating fire to adjacent combustible material. Special attention is called to the fact that switchboards...be built down to the floor, nor up to the ceiling. A space of at least 10 or 12 inches should be left between the floor and the board, and 3 feet, if...
Повний перегляд - Докладніше про цю книгу