Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors. Electric Lighting Specifications - Сторінка 171автори: Earle Abbott Merrilol - 1896 - 213 стор.Повний перегляд - Докладніше про цю книгу
| New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...apart, the distance between supports to be shortened if wires are liable to be disturbed. e. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that... | |
| Terrell Croft - 1920 - 488 стор.
...must be protected against abrasion where they pass through sheet metal pans, canopies, etc. Conductors must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered (unless made with some form of approvd splicing device) and covered... | |
| Sinclair Tousey - 1921 - 1372 стор.
...attached must be covered over their entire surface with at least two coats of waterproof paint. (/) Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that... | |
| Louis Denton Bliss - 1922 - 796 стор.
...They must be so spliced as to ,be both mechanically and electrically secure without solder. The joints must then be soldered to insure preservation and covered...with an insulation equal to that on the conductors. Service wires entering buildings must have drip-loops outside the holes through which the conductors... | |
| New York (N.Y.) - 1922 - 636 стор.
...provided with washers which will prevent, under reasonable usage, injury to the knobs or cleats. c. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered... | |
| Louis Denton Bliss - 1922 - 794 стор.
...S. Wires must be so spticed as to be mechanically and electrically secure without solder. The joints must then be soldered to insure preservation and covered with an insulation equal to that of the conductors. Stranded wires, except flexible cords, must be soldered before being fastened with... | |
| William Arthur Del Mar - 1924 - 224 стор.
...must not be of smaller sizes than No. 14 A. wg, except as allowed for fixture wire and cords. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some sort of approved splicing device and covered... | |
| Albert August Schuhler - 1924 - 416 стор.
...requirements of the National Electrical Code relating to splices and joints specify that conductors must be so spliced or joined as to be both mechanically and electrically secure prior to soldering. The joints must then be soldered to insure preservation, unless some form of approved... | |
| Horace Holden Thayer - 1924 - 414 стор.
...injury they shall be protected by suitable boxes or cages. Joints shall be so spliced or the parts so joined as to be both mechanically and 'electrically secure without solder. They shall then be soldered and properly insulated and further protected by waterproof tape. Also that the... | |
| 1939 - 1192 стор.
...watertight. *tFor statutory and source citations, see note to § 63.1. Page 781 Splices shall be so joined as to be both mechanically and electrically secure without solder. They shall then be soldered and properly insulated and further protected by waterproof tape. Changes or... | |
| |