" The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables. "
Agents' and Inspectators Pocket-book of Fire Protection - Сторінка 79
автори: George Velten Steeb - 1902 - 218 стор.
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: Lighting; Railways; Power stations

1905 - 480 стор.
...970 ........ 1.550 1,900,000 ........ 1.010 ........ 1,610 2,000,000 ........ 1,050 ........ 1,670 The lower limit is specified for rubber-covered wires...consideration in the above tables. The carrying capacity of Nos. 16 and 18, B. & S. gage wire is given, but no smaller than No. 14 is to be used. 300 400 500 590...
Повний перегляд - Докладніше про цю книгу

Management of Dynamo-electric Machinery: Parts 1-2

American School (Lansing, Ill.) - 1906 - 72 стор.
...1,600,000 890 1,430 1,700,000 930 1 .490 1,800,000 970 1.550 1,900,000 1,010 1,610 2,000,000 1,050 1,670 The lower limit Is specified for rubber-covered wires...consideration in the above tables. The carrying capacity of Nos. 10 and 18, B & S. gage wire is given, but no smaller than No. 14 is to be used. The safe carrying...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

1906 - 590 стор.
...1,600,000 890 1,430 1,700,000 930 1,490 1.800,000 970 1.550 1,900,000 1,010 1,610 2,000,000 1,050 1,670 The lower limit is specified for rubber-covered wires...deterioration of the high insulations by the heat of tho wire.-, but not from fear of igniting the insulation. The question of drop is not taken into consideration...
Повний перегляд - Докладніше про цю книгу

The Elements of Electrical Engineering: A Text Book for Technical ..., Том 1

William Suddards Franklin, William Esty - 1906 - 550 стор.
...The lower limit is specified for rubber covered wires to prevent gradual deterioration of the rubber by the heat of the wires, but not from fear of igniting the insulation. The question of vollage-drop is not taken into consideration in the above tables. Brown and Sharpe Gauge. Sectional...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring

1906 - 544 стор.
...capacity is 84 per cent. "of that given in the table for copper wire with the same kind of insulation. The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulation by the heat of the wires, but not from fear of igniting the insulation. The question of...
Повний перегляд - Докладніше про цю книгу

Handbook on Engineering ...

Henry Charles Tulley - 1907 - 1120 стор.
...700,000 500 760 800.000 550 840 90o,000 COO 920 The lower limit is specified for rubber-covered wires bo prevent gradual deterioration of the high insulations...not taken into consideration in the above tables. Insulation Resistance. — The wiring in any public building must test free from grounds ; ie, the...
Повний перегляд - Докладніше про цю книгу

Electric Light Wiring

Charles Edwin Knox - 1907 - 242 стор.
...1,600,000 890 1,430 1,700,000 930 1,490 1,800,000 970 1,550 1,900,000 1,010 1,610 2,000,000 1,050 1,670 The lower limit is specified for rubber-covered wires...wires, but not from fear of igniting the insulation. For all interior wiring, conductors should have a covering which shall act both as an electrical insulator...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.). - 1908 - 1260 стор.
...1,600,000 890 1,430 1,700,000 930 1,490 1 ,800,000 970 1,550 1,900,000 1,010 1,610 2,000,000 1,050 1,670 The lower limit is specified for rubber-covered wires,...above tables. The carrying capacity of sixteen and eighteen wire is given, but no smaller than fourteen is to be used, except as allowed under Rules 24-t...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...930. . . 1,490 1,800,000. . . 970... 1,550 1,900,000. . . 1,010. .. 1,610 2,000,000... 1,050... 1,870 The lower limit is specified for rubber-covered wires...consideration in the above tables. The carrying capacity of Nos. 16 and 18, B. & S. gage wire is given, but no smaller than No. 14 is to be used, except as allowed...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity, Том 4

1908 - 480 стор.
...1.600,000 890 1,430 1.700,000 .930 1,490 1,800.000 970 1.550 1,909.000 1.010 1,610 2,000,000 1,050 1,670 The lower limit Is specified for rubber-covered wires...question of drop is not taken into consideration in tho above tables. The carrying capacity of Nos 16 and 18, B & S. gage wire is given, but no smaller...