" ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material. "
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... - Сторінка 121
автори: Russell Robb - 1896 - 183 стор.
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

1906 - 590 стор.
...automatic cut-outs should not, however, be placed in the immediate vicinity of easily ignitible stuff, nor where exposed to inflammable gases or dust, or to flyings of combustible material, as the arcing produced whenever they break the circuit might cause a fire or explosion. When they are...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - 438 стор.
...automatic cut-outs should not, however, be placed in the immediate vicinity of easily ignitible stuff, nor where exposed to inflammable gases or dust, or to flyings of combustible material, as the arcing produced whenever they break the circuit might cause a fire or explosion. When they are...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.). - 1908 - 1260 стор.
...or circuit-breaker. . b. Must not be placed in the immediate vicinity of easily ignitable stuff, or where exposed to inflammable gases or dust, or to flyings of combustible material. c. Must, when exposed to dampness, either be enclosed in a water-proof box or mounted on porcelain...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring ...

International Correspondence Schools - 1908 - 660 стор.
...switch or circuit-breaker. b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material. In starch and candy factories, grain elevators, flouring mills, and buildings used for woodworking...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...each wire. These cut-outs must not be placed in the immediate vicinity of easily ignitible stuff, or where exposed to inflammable gases, or dust or to flyings of combustible material. h. The wires inside building shall be of copper not less than No. 16 B. & S. gage, and must have insulation...
Повний перегляд - Докладніше про цю книгу

Medical Electricity, Röntgen Rays and Radium: With a Practical Chapter on ...

Sinclair Tousey - 1915 - 1418 стор.
...or circuit-breaker. (6) Must not be placed in the immediate vicinity of easily ignitible stuff, or where exposed to inflammable gases or dust or to flyings of combustible material. RUBBER-COVERED WIRE. (a) Copper for conductors must be thoroughly tinned. INSULATION FOR VOLTAGES BETWEEN...
Повний перегляд - Докладніше про цю книгу

Digest of the City of Little Rock, Arkansas

Little Rock (Ark.). - 1915 - 770 стор.
...switch or circult->breaker. (b) Must not be placed in the immediate vicinity of easily ignitiWe stuff or where exposed to inflammable gases or dust or to flyings of combustible material, (c) Must, when exposed to dampness, either be enclosed in a moisture-proof box or mounted on porcelain...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 332 стор.
...placed where exposed to mechanical injury nor in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material. Where the occupancy of a building is such that switches, cut-outs, etc., cannot be located so as not...
Повний перегляд - Докладніше про цю книгу

Proceedings of the Board of Aldermen of the City of New York, Том 1

New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...each wire. These cut-outs must not be placed in the immediate vicinity of easily ignitable stuff, or where exposed to inflammable gases, or dust or to flyings of combustible material. h. The wires inside building shall be of copper not less than No. 16 B. & S. gauge, and muft have insulation...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1920 - 488 стор.
...each wire. These cut-outs must not be placed in the immediate vicinity of easily ignitible stuff, or where exposed to inflammable gases or dust or to flyings of combustible material. 85h. f/. SIGNALING SYSTEMS 10 AMP. CAPACITY. NOT UNDERGROUND. The wires inside building shall be of...