" Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors. "
New Catechism of Electricity: A Practical Treatise - Сторінка 386
автори: Nehemiah Hawkins - 1896 - 541 стор.
Повний перегляд - Докладніше про цю книгу

Building Code of Baltimore: Being Ordinance No. 155 of the Mayor and City ...

Baltimore (Md.) - 1908 - 514 стор.
...SolicinK of outside wires. ally and electrically secure without solder. The joints of outside wires shall then be soldered to insure preservation, and covered...with an insulation equal to that on the conductors. All joints shall be soldered, even if made with some form of patent splicing device. wb™d££!ri>1"...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. /. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Report of the Commissioner of Corporations on Transportation by Water in the ...

United States. Bureau of Corporations - 1909 - 648 стор.
...Splices or taps in conductors must be avoided as far as possible. Where it is necessary to make them they must be so spliced or joined as to be both mechanically...secure without solder. They must then be soldered, to ensure preservation, covered with an insulating compound equal to the insulation of the wire, and further...
Повний перегляд - Докладніше про цю книгу

The Texas Civil Appeals Reports: Cases Argued and Determined in the ..., Том 46

Texas. Court of Civil Appeals - 1909 - 760 стор.
...enacted, in substance, that live wires must have an approved weather or rubber insulating covering, and be so spliced or joined as to be both mechanically and electrically secure without solder, and the joints must then be soldered to insure preservation and covered with an insulation equal to...
Повний перегляд - Докладніше про цю книгу

Revised Ordinances of the City of Peoria, Illinois

Peoria (Ill.) - 1910 - 904 стор.
...may be used on one circuit. No service wires shall be smaller than No. 10 B. and S. gauge. All joints must be so spliced or joined as to be both mechanically and electrically secure without soldering. The joints must be soldered to insure preservation and covered with 1 layer rubber tape,...
Повний перегляд - Докладніше про цю книгу

Practical Operation of Arc Lamps

National Carbon Company, Inc - 1911 - 84 стор.
...be used. Tie wires must have an insulation equal to that of the conductors which they confine. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Electric Wiring

Joseph Gerald Branch - 1913 - 316 стор.
...one inch from the surface wired over, supports to be placed at least every four and one-half feet. f. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: A General Reference Work on Direct ..., Том 5

1913 - 492 стор.
...extend outside of the casing, the flameproof covering will not be required on the motor leads. (5) Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered and covered with an insulation equal to that on the conductors. Joints...
Повний перегляд - Докладніше про цю книгу

Simultaneous Telephony and Telegraphy: Telephones; Telephone Train ...

International Correspondence Schools - 1913 - 654 стор.
...(usually leather) which will prevent under reasonable usage, injury to the knobs or cleats. c. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered...
Повний перегляд - Докладніше про цю книгу

Electric Railways: A Comprehensive Treatise on Modern Electric Railway ...

Henry H. Norris, American School (Lansing, Ill.) - 1913 - 370 стор.
...extend outside of the casing, the flameproof covering will not be required on the motor leads. (5) I^ust be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered and covered with an insulation equal to that on the conductors. Joints...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF