| New York (N.Y.) - 1922 - 636 стор.
...provided with washers which will prevent, under reasonable usage, injury to the knobs or cleats. c. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered... | |
| Louis Denton Bliss - 1922 - 794 стор.
...S. Wires must be so spticed as to be mechanically and electrically secure without solder. The joints must then be soldered to insure preservation and covered with an insulation equal to that of the conductors. Stranded wires, except flexible cords, must be soldered before being fastened with... | |
| William Arthur Del Mar - 1924 - 224 стор.
...must not be of smaller sizes than No. 14 A. wg, except as allowed for fixture wire and cords. Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some sort of approved splicing device and covered... | |
| Albert August Schuhler - 1924 - 416 стор.
...requirements of the National Electrical Code relating to splices and joints specify that conductors must be so spliced or joined as to be both mechanically and electrically secure prior to soldering. The joints must then be soldered to insure preservation, unless some form of approved... | |
| Horace Holden Thayer - 1924 - 414 стор.
...injury they shall be protected by suitable boxes or cages. Joints shall be so spliced or the parts so joined as to be both mechanically and 'electrically secure without solder. They shall then be soldered and properly insulated and further protected by waterproof tape. Also that the... | |
| 1939 - 1192 стор.
...watertight. *tFor statutory and source citations, see note to § 63.1. Page 781 Splices shall be so joined as to be both mechanically and electrically secure without solder. They shall then be soldered and properly insulated and further protected by waterproof tape. Changes or... | |
| United States. Coast Guard - 1942 - 166 стор.
...and machinery spaces, galley, and those exposed to weather shall be watertight. Splices shall be so joined as to be both mechanically and electrically secure without solder. They shall then be soldered and properly insulated and further protected by waterproof tape. Changes or... | |
| Rodney Hitt - 1911 - 424 стор.
...extend outside of the casing, the flame-proof covering will not be required on the motor leads. 5. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered and covered with an insulation equal to that on the conductors. Joints... | |
| 1949 - 708 стор.
...machinery spaces, galley, and those exposed to weather shall be watertight. (6) Splices shall be so Joined as to be both mechanically and electrically secure without solder. They shall then be soldered and properly insulated and further protected by waterproof tape. (7) Changes... | |
| Calvin Franklin Swingle - 1906 - 488 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. /. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that... | |
| |