Пошук Зображення Карти YouTube Новини Gmail Диск Календар Більше »
Увійти
Книги Книги 21 - 30 з 68 у Must be so spliced or joined as to be both mechanically and electrically secure without....
" Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors. "
Electric Wiring for the Use of Architects, Underwriters, and the Owners of ... - Сторінка 89
автори: Russell Robb - 1896 - 183 стор.
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring

1906 - 550 стор.
...or taps in conductors must be avoided as far as possible. Where it is necessary to make them, they must be so spliced or joined as to be both mechanically...They must then be soldered, to insure preservation, covered with an insulating compound equal to the insulation of the wire, and further protected by a...
Повний перегляд - Докладніше про цю книгу

American electric railway practice

Albert Bledsoe Herrick, Edward Carlisle Boynton - 1907 - 403 стор.
...flame-proof compound. NOTE.— This rule will be interpreted to include the leads from the motors. 5. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered and covered with an insulation equal to that on the conductors. NOTE.—...
Повний перегляд - Докладніше про цю книгу

Electric light wiring

Charles Edwin Knox - 1907 - 219 стор.
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. /. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

American Electric Railway Practice

Albert Bledsoe Herrick, Edward Carlisle Boynton - 1907 - 403 стор.
...flame-proof compound. NOTE. — This rule will be interpreted to include the leads from the motors. 5. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered and covered with an insulation equal to that on the conductors. NOTE.—...
Повний перегляд - Докладніше про цю книгу

Storage batteries ; incandescent lighting ; arc lighting ; interior wiring ...

International Correspondence Schools - 1908
...larger wire. b. Tie-wires must have an insulation equal to that of the conductors they confine. c. Must be so spliced or joined as to be both mechanically...must then be soldered to insure preservation, and the joint covered with an insulation equal to that on the conductors. Stranded wires must be soldered...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.)., James C. Michael, Hiram David Frankel - 1908 - 1245 стор.
...24-t and 4o-b. b. Tie wire must have an insulation equal to that of the conductors they confine. c. Must be so spliced or joined as to be both mechanically...must then be soldered to insure preservation, and the joint covered with an insulation equal to that on the conductors. Stranded wires must be soldered...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring ...

1908 - 639 стор.
...or taps in conductors must be avoided as far as possible. Where it is necessary to make them, they must be so spliced or joined as to be both mechanically...They must then be soldered, to insure preservation, covered with an insulating compound equal to the insulation of the wire, and further protected by a...
Повний перегляд - Докладніше про цю книгу

Building Code of Baltimore: Being Ordinance No. 155 of the Mayor and City ...

Baltimore (Md.) - 1908 - 506 стор.
...SolicinK of outside wires. ally and electrically secure without solder. The joints of outside wires shall then be soldered to insure preservation, and covered...with an insulation equal to that on the conductors. All joints shall be soldered, even if made with some form of patent splicing device. wb™d££!ri>1"...
Повний перегляд - Докладніше про цю книгу

Modern electrical construction...

Henry Charles Horstmann, Victor Hugo Tousley - 1908
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. /. Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that...
Повний перегляд - Докладніше про цю книгу

Report of the Commissioner of Corporations on Transportation by Water in the ...

United States. Bureau of Corporations - 1909
...Splices or taps in conductors must be avoided as far as possible. Where it is necessary to make them they must be so spliced or joined as to be both mechanically...secure without solder. They must then be soldered, to ensure preservation, covered with an insulating compound equal to the insulation of the wire, and further...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг