" Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under,... "
Telegraphic Journal and Monthly Illustrated Review of Electrical Science - Сторінка 292
1891
Повний перегляд - Докладніше про цю книгу

Electric Wiring

Joseph Gerald Branch - 1913 - 316 стор.
...prevent them from moving along the wire. f. Must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...
Повний перегляд - Докладніше про цю книгу

Simultaneous Telephony and Telegraphy: Telephones; Telephone Train ...

International Correspondence Schools - 1913 - 654 стор.
...to prevent the tube sliding along. /. Wires must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...
Повний перегляд - Докладніше про цю книгу

Medical Electricity, Röntgen Rays and Radium: With a Practical Chapter on ...

Sinclair Tousey - 1915 - 1418 стор.
...placed as nearly above the pipe as possible. (/) Must be so placed in wet places that an air-space will be left between conductors and pipes in crossing,...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...
Повний перегляд - Докладніше про цю книгу

Digest of the City of Little Rock, Arkansas

Little Rock (Ark.). - 1915 - 770 стор.
...nonconductor, creating a permanent separation, (f) Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they can not cotne in contact with the pipe accidentally. Wires should be run over, rather than under, pipes...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1915 - 332 стор.
...arranged so that an air space will be left between conductors and pipes in crossing, and the former should be run in such a way that they cannot come in contact with the pipe accidentally. Where one wire crosses another wire the best and usual means of separating them is by a porcelain tube...
Повний перегляд - Докладніше про цю книгу

Electrical Construction: an Elementary Course for Vocational Schools

Walter Benedict Weber - 1916 - 164 стор.
...some continuous and firmly-fixed non-conductor. Must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...cannot come in contact with the pipe accidentally. The installation of electrical conductors in wood molding, or on insulators in elevator shafts will...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1917 - 446 стор.
...allowed by special permission. 16/. If/. WIRES. Must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power as Adopted by the Fire ...

Harry Cooke Cushing - 1917 - 374 стор.
...arranged so that an air space will be left between conductors and pipes in crossing, and the former should be run in such a way that they cannot come in contact with the pipe accidentally. Where one wire crosses another wire the best and usual means of separating them is by a porcelain tube...
Повний перегляд - Докладніше про цю книгу

Wiring for Light and Power: A Detailed and Fully Illustrated Commentary on ...

Terrell Croft - 1920 - 488 стор.
...allowed by special permission. 16/. 17. WIRES. Must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...
Повний перегляд - Докладніше про цю книгу

Proceedings of the Board of Aldermen of the City of New York, Том 1

New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...necessary, be allowed by special permission. f. Wires must be so placed in wet places that an air space will be left between conductors and pipes in crossing,...with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause...