" Must be placed at every point where a change Is made in the size of wire (unless the cut-out In the larger wire will protect the smaller.) (c) Must be in plain sight, or enclosed in an approved cabinet, and readily accessible. "
Carpentry and Contracting: A Practical Reference Work on Carpentry, Building ... - Сторінка 309
1919
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

Louis Derr - 1906
...well as the current and voltage for which the device is designed. Cut-outs or circuit breakers should be placed at every point where a change is made in the size of wire, unless such a device in the larger wire will protect the smaller. They should never be placed in canopies...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring

1906 - 550 стор.
...put up and the molding secured to this. b. Capping must be secured by brass screws. Cut-Outs — a. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). b. In places such as upper...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907
...well as the current and voltage for which the device is designed. Cut-outs or circuit breakers should be placed at every point where a change is made in the size of wire, unless such a device in the larger wire will protect the smaller. They should never be placed in canopies...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring ...

International Correspondence Schools - 1908 - 639 стор.
...the next fuse back is small enough to properly protect the wires inside the building in question. b. Must be placed at every point where a change is made in the size of wire (unless the cut-out in the larger wire will protect the smaller). 29. The object of a fusible cut-out is to protect...
Повний перегляд - Докладніше про цю книгу

Compiled Ordinances of the City of St. Paul, Minnesota

Saint Paul (Minn.). - 1908 - 1245 стор.
...is inside the building, the cutout required by this section must be placed so as to protect it. b. Must be placed at every point where a change is made in the size of wire (unless the cut-out in the larger wire will protect the smaller). c. To be enclosed in an approved cabinet, or...
Повний перегляд - Докладніше про цю книгу

Storage Batteries ; Incandescent Lighting ; Arc Lighting ; Interior Wiring ...

International Correspondence Schools - 1908 - 639 стор.
...put up and the molding secured to this. b. Capping must be secured by brass screws. Cut-Outs — a. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). b. In places such as upper...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 329 стор.
...freight compartment may be separately controlled. 76. Cut-Outs. (For construction rules, see No. 52.) a. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). b. In such places as upper-decks,...
Повний перегляд - Докладніше про цю книгу

Report of the Commissioner of Corporations on Transportation by Water in the ...

United States. Bureau of Corporations - 1909
...always visible with the name of trie maker and current and voltage for which the device is designed (e) Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller) . (d) When placed anywhere...
Повний перегляд - Докладніше про цю книгу

Ordinances Relating to Buildings, City of Seattle

1910 - 216 стор.
...building, inside the walls thereof, and arranged to cut oft the entire current in the building. They must be placed at every point where a change is made in the size of the wire, provided the cut-out in the larger wire will not protect the smaller: and must be so placed...
Повний перегляд - Докладніше про цю книгу

Practical Operation of Arc Lamps

National Carbon Company, Inc - 1911 - 75 стор.
...point where they enter the building and arranged to cut off the entire circuit from the house. Cut-outs must be placed at every point where a change is made in the size of wire, unless the cut-out in the larger wire will protect the smaller. No set of incandescent lamps requiring more than...