" Must be placed at every point where a change Is made in the size of wire (unless the cut-out In the larger wire will protect the smaller.) (c) Must be in plain sight, or enclosed in an approved cabinet, and readily accessible. "
Carpentry and Contracting: A Practical Reference Work on Carpentry, Building ... - Сторінка 309
1919
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks for ..., Том 13

1902
...is inside the building, the cutout required by this section must be placed so as to protect it. b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller]. This (b) means unless the current carried by...
Повний перегляд - Докладніше про цю книгу

Standard wiring for electric light and power: as adopted by the Fire ...

Harry Cooke Cushing - 1902 - 152 стор.
...maker, and current and voltage for which the device is designed. Cut-outs or circuit breakers should be placed at every point where a change is made in the size of wire, unless such a device in the larger wire will protect the smaller. They should never be placed in canopies...
Повний перегляд - Докладніше про цю книгу

Agents' and Inspectators Pocket-book of Fire Protection

George Velten Steeb - 1902 - 218 стор.
...enter the building and inside the walls, and arranged to cut off the entire current from the building, must be placed at every point where a change is made in the size of the wire, unless the cut-out in the larger wire will protect the smaller, be in plain sight, or inclosed...
Повний перегляд - Докладніше про цю книгу

An Elementary Book on Electricity and Magnetism and Their Applications: A ...

Dugald Caleb Jackson, John Price Jackson - 1902 - 482 стор.
...the rated carrying capacity of the smallest wire which they protect. It is customary to place fuses at every point where a change is made in the size of wire, even where small fixtures or drop cords are attached to the tap lines, and not more than a dozen sixteen-candle-power...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering; a Complete Manual of Steam and Machine ..., Том 4

1902
...upon which the fuse may be mounted. Cut-outs should be placed where the mains enter the building, and at every point where a change is made in the size of the wire. A cut-out cabinet is a box in which several cut-outs may be located, being a local centre...
Повний перегляд - Докладніше про цю книгу

Science and Industry, Том 7

1902
...cut off the entire current from the building. They must be placed at every point throughout a system, where a change is made in the size of wire (unless the cut-out in the larger wire will protect the smaller). All cut-outs must be in plain sight, or enclosed...
Повний перегляд - Докладніше про цю книгу

Electricity, light, power

American School (Chicago, Ill.) - 1903
...upon which the fuse may be mounted. Cut-outs should be placed where the mains enter the building, and at every point where a change is made in the size of the wire. A cut-out cabinet is a box in which several cut-outs may be located, being a local centre...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: Current measurements; Wiring; Telegraph

1905
...well as the current and voltage for which the device is designed. Cut-outs or circuit breakers should be placed at every point where a change is made in the size of wire, unless such a device in the larger wire will protect the smaller. They should never be placed in canopies...
Повний перегляд - Докладніше про цю книгу

The Practical Engineer's Handbook: The Care and Management of Electric Power ...

Norman Hugh Schneider - 1905 - 274 стор.
...is made for larger currents. Cartridge fuse cut-outs are made for wider ranges of current. Cut-outs must be placed at every point where a change is made in the size of the wire except where a cut-out in the larger wire will protect the smaller wire, and must be placed...
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks ..., Том 14,Частина 2

1906
...put up and the molding secured to this. b. Capping must be secured by brass screws. Cut-Outs — a. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). b. In places such as upper...