...inside the building in question. 1>. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller (see No. 18)123. Automatic Cut-outs (Fuses and Circuit-Breakers) — Continued. vided the neutral wire... | |
| Dallas (Tex.). - 1914 - 266 стор.
...and branch circuits entering other buildings need not ordinarily be protected by entrance fuses. (e) Must be placed at every point where a change is made in the size of wire, unless the cut-out in the large wire will protect the smaller. (f ) No main or branch fuse block... | |
| Little Rock (Ark.). - 1915 - 770 стор.
...the building and inside the walls, and arranged to cut off the entire current from the building, (b) Must be placed at every point where a change Is made in the size of wire (unless the cut-out In the larger wire will protect the smaller.) (c) Must be in plain sight,... | |
| Harry Cooke Cushing - 1915 - 332 стор.
...maker, and current and voltage for which the device is designed. Cut-outs or circuit breakers should be placed at every point where a change is made in the size of wire, unless such a device in the larger wire will protect the smaller. They should never be placed... | |
| George Alvin Cowee - 1916 - 494 стор.
...constructed that an arc cannot be maintained across its terminals by the fusing of the metal. Fuses should be placed at every point where a change is made in the size of the wire, unless the one in the larger wire will protect the smaller. Extra fuses should be kept in a handy place where... | |
| Terrell Croft - 1917 - 446 стор.
...wires from a public service company's mains. 236. If/. AUTOMATIC CUT-OUTS (FUSES AND CIRCUIT BREAKERS). Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller (see No. 18)]. Where the size... | |
| Harry Cooke Cushing - 1917 - 374 стор.
...building in question. Cut-outs should be placed at every point where a change is made in the size of wire [unless the cutout in the larger wire will protect the smaller (see current carrying capacity of wires page 91)]. Cut-outs should not be placed in any permanently... | |
| 1919 - 444 стор.
...current is a problem for the electrical engineer. The point to be noted here is that fuses or breakers must be placed at every point where a change is made in the size of wire unless the fuse next back will also protect the smaller wire. The rated capacity of fuses must... | |
| Terrell Croft - 1920 - 488 стор.
...above described. Distribution Box} 1 II -• 23&. If/. AUTOMATIC CUT-OUTS (FUSES AND CIRCUIT BREAKERS). Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller (see No. 18)]. Where the size... | |
| New York (N.Y.). Board of Aldermen - 1920 - 904 стор.
...is small enough to properly protect the wires inside the building in question. b. Automatic cut-outs must be placed at every point where a change is made in the size of wire, unless the cut-out in the larger wire will protect the smaller (see §418 of this chapter). This... | |
| |