Storage Batteries Simplified, Operating Principles--care and Industrial Applications: A Complete, Non-technical But Authoritative Treatise Discussing the Development of the Modern Storage Battery, Outlining the Basic Operation of the Leading TypesNorman W. Henley publishing Company, 1917 - 196 стор. |
З цієї книги
Результати 11-15 із 55
Сторінка 58
... voltage has attained its maximum . It should be understood thať sulphating is a normal as well as an abnormal process in the charge and discharge of storage bat- teries , and the difference is in the degree , not the process . The ...
... voltage has attained its maximum . It should be understood thať sulphating is a normal as well as an abnormal process in the charge and discharge of storage bat- teries , and the difference is in the degree , not the process . The ...
Сторінка 59
... voltage and gravity readings show no further increase for at least ten hours and an absolute maximum has been reached . In serious cases it may be advisable to even exceed this time in order to make absolutely sure that all sulphate is ...
... voltage and gravity readings show no further increase for at least ten hours and an absolute maximum has been reached . In serious cases it may be advisable to even exceed this time in order to make absolutely sure that all sulphate is ...
Сторінка 61
... voltage throughout the battery is taken in the regular way , cadmium readings can be taken by inserting the rubber ... voltage already taken will represent approximately the negative cadmium reading . For example , if the positive ...
... voltage throughout the battery is taken in the regular way , cadmium readings can be taken by inserting the rubber ... voltage already taken will represent approximately the negative cadmium reading . For example , if the positive ...
Сторінка 62
... voltage after three hours but the slow rise 2.2 2.1 2.Q Positive to Cadmium Cell Voltage S +101 1.9 - 1.8 0.2 1.7 : ལྦ 0.1 Negative to Cadmium- ITTI 2 Hours 3 T 4 L Fig . 22. - Curves Illustrating the Discharge of a Cell During a Cad ...
... voltage after three hours but the slow rise 2.2 2.1 2.Q Positive to Cadmium Cell Voltage S +101 1.9 - 1.8 0.2 1.7 : ལྦ 0.1 Negative to Cadmium- ITTI 2 Hours 3 T 4 L Fig . 22. - Curves Illustrating the Discharge of a Cell During a Cad ...
Сторінка 66
... voltage of the Edison batteries . The average voltage during discharge is but 1.2 volts per cell , and is not as constant as is the case with a lead battery , the voltage of which may be as high as 2.5 volts per cell . An Edison 6.5 ...
... voltage of the Edison batteries . The average voltage during discharge is but 1.2 volts per cell , and is not as constant as is the case with a lead battery , the voltage of which may be as high as 2.5 volts per cell . An Edison 6.5 ...
Інші видання - Показати все
Загальні терміни та фрази
25 cents 50 cents A. A. HOUGHTON active material alkaline battery alternating current amperage ampere-hours amperes apparatus armature automobile boilers burning busbar cadmium capacity carbon charging rate chart chemical circuit coil Concrete condition connected connector construction contains cover device direct current dynamo edition electric electrolyte elements Exide flame flow fully charged fully illustrated glass grid heating hydrometer ignition system inches installation insulating lamp lathes lead plate lead-plate lighting Locomotive lugs machine magnet manufacture mechanical metal method modern molds motor negative plate O'CONOR SLOANE operation outfit oxide PAGÉ plants plumbing positive plate pounds practical Price putty knife repair resistance Rheostat rubber sealing compound sealing nuts shown at Fig shows specific gravity steam steel storage battery Storage Battery Company Strap sulphate switch switchboard tank tery tion treatise trouble tube Valve Gear vent voltage volts watt-hours wire wood separators zinc