Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 6-10 із 29
Сторінка 33
... vent hub should be on the same level as the main hub on the fitting . In Fig . 36 the branch of the inverted Y should be made at 45 deg . , and not at 30 deg . , as shown in No. 2. No. 3 shows the correct form of the vent fitting used ...
... vent hub should be on the same level as the main hub on the fitting . In Fig . 36 the branch of the inverted Y should be made at 45 deg . , and not at 30 deg . , as shown in No. 2. No. 3 shows the correct form of the vent fitting used ...
Сторінка 34
... vent from the upper vent- ed T - Y is shown offset into the main vent through a vent T turned slightly from its straight position . In laying out these two exercises , first put in the two main lines of pipes without hubs , the line of vent ...
... vent from the upper vent- ed T - Y is shown offset into the main vent through a vent T turned slightly from its straight position . In laying out these two exercises , first put in the two main lines of pipes without hubs , the line of vent ...
Сторінка 38
... vent lines are to be run , then draw them without hubs , and draw the fixture in its position . Very often it is best as in the case of the sink in Fig . 39 , to show the waste at the further end of the sink , as it can readily be seen ...
... vent lines are to be run , then draw them without hubs , and draw the fixture in its position . Very often it is best as in the case of the sink in Fig . 39 , to show the waste at the further end of the sink , as it can readily be seen ...
Сторінка 42
... vent tees also face the front , so that the tee branch does not ap- pear , merely the circular form of the end of the branch . Again , the upper fitting in Fig . 47 , through which the vent line enters the stack , stands with its branch ...
... vent tees also face the front , so that the tee branch does not ap- pear , merely the circular form of the end of the branch . Again , the upper fitting in Fig . 47 , through which the vent line enters the stack , stands with its branch ...
Сторінка 64
... vent and waste . In Fig . 73 they are one behind the other , the vent being in front . Being of the same diameter , Fresh Air Inlet Bath Room Stack Kitchen Stack Pantry Stack , front elevation of it , that is , by viewing the work from ...
... vent and waste . In Fig . 73 they are one behind the other , the vent being in front . Being of the same diameter , Fresh Air Inlet Bath Room Stack Kitchen Stack Pantry Stack , front elevation of it , that is , by viewing the work from ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 3rd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory lines of pipe main drain main line main stack main trap main Vent Line mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines tee square thread tical tion Toilet Room Stack triangle valve vertical lines Wash Trays waste water closet wrought iron