... vent from the upper vent- ed T - Y is shown offset into the main vent through a vent T turned slightly from its straight position . In laying out these two exercises , first put in the two main lines of pipes without hubs , the line of vent ...
... vent from the upper vent- ed T - Y is shown offset into the main vent through a vent T turned slightly from its straight position . In laying out these two exercises , first put in the two main lines of pipes without hubs , the line of vent ...
Сторінка 38
... vent lines are to be run , then draw them without hubs , and draw the fixture in its position . Very often it is best as in the case of the sink in Fig . 39 , to show the waste at the further end of the sink , as it can readily be seen ...
... vent lines are to be run , then draw them without hubs , and draw the fixture in its position . Very often it is best as in the case of the sink in Fig . 39 , to show the waste at the further end of the sink , as it can readily be seen ...
Сторінка 42
... vent tees also face the front , so that the tee branch does not ap- pear , merely the circular form of the end of the branch . Again , the upper fitting in Fig . 47 , through which the vent line enters the stack , stands with its branch ...
... vent tees also face the front , so that the tee branch does not ap- pear , merely the circular form of the end of the branch . Again , the upper fitting in Fig . 47 , through which the vent line enters the stack , stands with its branch ...
Сторінка 64
... vent and waste . In Fig . 73 they are one behind the other , the vent being in front . Being of the same diameter , Bath Room Stack Kitchen Stack Fresh Air Inlet Pantry Stack , front elevation of it , that is , by viewing the work from ...
... vent and waste . In Fig . 73 they are one behind the other , the vent being in front . Being of the same diameter , Bath Room Stack Kitchen Stack Fresh Air Inlet Pantry Stack , front elevation of it , that is , by viewing the work from ...
Сторінка 67
... Vent from Bath Trap own Fig . 78 - Cellar. 3rd . Flooc 2nd Floor 1st . Floor ! - FIG . 74 . W. C Back Air W.C. Back Aic to find a layout that can be handled in this way , of work of such extent , but whenever possible , this course ...
... Vent from Bath Trap own Fig . 78 - Cellar. 3rd . Flooc 2nd Floor 1st . Floor ! - FIG . 74 . W. C Back Air W.C. Back Aic to find a layout that can be handled in this way , of work of such extent , but whenever possible , this course ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron
Популярні уривки
Сторінка 52 - Shade Lines. The light is assumed to come from the upper left hand corner of the drawing at an angle of 45 degrees to all horizontal and vertical lines.