Electric Lighting SpecificationsW. J. Johnstone Company, Limited, 1892 - 176 стор. |
З цієї книги
Результати 6-10 із 14
Сторінка 52
... unless otherwise specified , erect the following appa- ratus and material : of dynamo ( s ) ( each ) having a capacity c . p . , incandescent lamps . The maximum voltage at the terminals of the dynamo ( s ) shall not exceed -- volts at ...
... unless otherwise specified , erect the following appa- ratus and material : of dynamo ( s ) ( each ) having a capacity c . p . , incandescent lamps . The maximum voltage at the terminals of the dynamo ( s ) shall not exceed -- volts at ...
Сторінка 58
... unless otherwise specified , erect the following appa- ratus and material : constant potential , alternating cur- rent dynamo ( s ) ( each ) having a capacity of c . p . , volt incandescent lamps . The maximum voltage at the terminals ...
... unless otherwise specified , erect the following appa- ratus and material : constant potential , alternating cur- rent dynamo ( s ) ( each ) having a capacity of c . p . , volt incandescent lamps . The maximum voltage at the terminals ...
Сторінка 61
... unless lights are oper- ated therefrom , in which case a switch and cut out shall be placed in the main circuit before branching off to the various dynamos . There shall be provided the following num - 46 . Converters . bers and sizes ...
... unless lights are oper- ated therefrom , in which case a switch and cut out shall be placed in the main circuit before branching off to the various dynamos . There shall be provided the following num - 46 . Converters . bers and sizes ...
Сторінка 63
... unless otherwise specified , erect the following appa- ratus and material : 54. Dynamo ( s ) . " A dynamo capacity ELECTRIC LIGHTING SPECIFICATIONS . 63 Switchboard Switchboard Apparatus and Connections Circuits ALTERNATING CURRENT OR ...
... unless otherwise specified , erect the following appa- ratus and material : 54. Dynamo ( s ) . " A dynamo capacity ELECTRIC LIGHTING SPECIFICATIONS . 63 Switchboard Switchboard Apparatus and Connections Circuits ALTERNATING CURRENT OR ...
Сторінка 71
... unless otherwise specified , install the following apparatus and material : 64. Circuits . arc light dynamo ( s ) ( each ) having a 65. Dynan : o ( s ) . c . p . , ampère , capacity of volt arc lamps . 200 ५.८ Each dynamo shall be ...
... unless otherwise specified , install the following apparatus and material : 64. Circuits . arc light dynamo ( s ) ( each ) having a 65. Dynan : o ( s ) . c . p . , ampère , capacity of volt arc lamps . 200 ५.८ Each dynamo shall be ...
Інші видання - Показати все
Загальні терміни та фрази
Age money Alternating Current ampère meter apparatus appliances arc lamps armature attached automatic baseframe bidder shall fill bids building c. p. lamps cables candle power capacity carried ceiling cent centre of distribution cleats conductors conduit connections contractor shall furnish cross-arms cuits cut-out boxes cut-outs and switches Direct Current double-pole dynamo or circuit dynamos Trade number erect the following fastened fill out completely fixture foundation(s full load fuses hand regulator incandescent lamps inches incombustible bases installation insulated wire insulation resistance junction boxes knife switch least lightning arresters main wires ments moisture moisture-proof molding necessary non-combustible number of lights number or designation ohms operation outlets pipes placed plant porcelain potential pressure proper protected pulleys purchaser Rating of exciters riser feeder schedule securely set screws shunt Sockets soldered spark arresters specification steam struction switchboard taps three-wire tightened tion tube two-wire voltage voltmeter volts walls waterproof wire smaller