Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 6-10 із 13
Сторінка 53
... serve to show how the principles which we have discussed above , are applied on the shading of plumbing drawings . In putting in the shade lines , they are usually drawn heavy at the outset , but it may possibly be easier for beginners ...
... serve to show how the principles which we have discussed above , are applied on the shading of plumbing drawings . In putting in the shade lines , they are usually drawn heavy at the outset , but it may possibly be easier for beginners ...
Сторінка 64
... serving the kitchen fixtures would also come in line with each other , and this as we already know , does not make the drawing any clearer . Conse- quently , conditions being as they are , it is advisable to make separate elevations of ...
... serving the kitchen fixtures would also come in line with each other , and this as we already know , does not make the drawing any clearer . Conse- quently , conditions being as they are , it is advisable to make separate elevations of ...
Сторінка 79
... serving the toilet room passes up on one of the cellar piers , as shown by the cellar plan , and this fact is also shown on the elevation . The stack is run on the first floor through the closet , and also through closet on the two ...
... serving the toilet room passes up on one of the cellar piers , as shown by the cellar plan , and this fact is also shown on the elevation . The stack is run on the first floor through the closet , and also through closet on the two ...
Сторінка 82
... served by stack C on the second and third floors . In this elevation we have shown the main line of back air pipe connected at its lower end , back into the stack , which makes a better piece of work than The only other point in ...
... served by stack C on the second and third floors . In this elevation we have shown the main line of back air pipe connected at its lower end , back into the stack , which makes a better piece of work than The only other point in ...
Сторінка 87
... serving the fixtures connecting into stacks C and D , appear behind these stacks , and as the main vents in these zontal branches in the cellar , which con- nect into the main line for soil pipe . In Fig . 105 we get simply the end view ...
... serving the fixtures connecting into stacks C and D , appear behind these stacks , and as the main vents in these zontal branches in the cellar , which con- nect into the main line for soil pipe . In Fig . 105 we get simply the end view ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron
Популярні уривки
Сторінка 52 - Shade Lines. The light is assumed to come from the upper left hand corner of the drawing at an angle of 45 degrees to all horizontal and vertical lines.