Electric Lighting SpecificationsW. J. Johnstone Company, Limited, 1892 - 176 стор. |
З цієї книги
Результати 6-10 із 12
Сторінка 83
Earl Abbott Merrill. 101. Additions and Deduc- tions . While the schedule is intended to represent very closely the number of lights and outlets to be wired to , yet , as some changes may become necessary during the process of ...
Earl Abbott Merrill. 101. Additions and Deduc- tions . While the schedule is intended to represent very closely the number of lights and outlets to be wired to , yet , as some changes may become necessary during the process of ...
Сторінка 102
... Schedules . on the system adopted and on local con- ditions ; it is sometimes absolutely necessary that they shall ... schedule is intended to represent very closely the number of lights to be installed , yet as some changes may become ...
... Schedules . on the system adopted and on local con- ditions ; it is sometimes absolutely necessary that they shall ... schedule is intended to represent very closely the number of lights to be installed , yet as some changes may become ...
Сторінка 103
... schedule can often be incorporated in the fixture schedule . The catalogue num- ber of fixtures is added in this schedule in order to keep in mind the exact fixture for which a given shade is intended , thus insuring against mistakes in ...
... schedule can often be incorporated in the fixture schedule . The catalogue num- ber of fixtures is added in this schedule in order to keep in mind the exact fixture for which a given shade is intended , thus insuring against mistakes in ...
Сторінка 104
... schedule for switches can also be used for meters , but in this case the current consumed by the lamp should be given , and it should be clearly specified whether the meter is to measure direct currents only , alternating currents only ...
... schedule for switches can also be used for meters , but in this case the current consumed by the lamp should be given , and it should be clearly specified whether the meter is to measure direct currents only , alternating currents only ...
Сторінка 105
Earl Abbott Merrill. LAMP OUTLET SCHEDULE . One Light . Two Light . Three Light . Four Light . Six Light . Light . Totals . FIRST FLOOR . Hall .. 1 1 2 3 Manager's Office . 2 1 1 1 5 13 Secretary's Office ..... 1 1 1 3 6 Consultation ...
Earl Abbott Merrill. LAMP OUTLET SCHEDULE . One Light . Two Light . Three Light . Four Light . Six Light . Light . Totals . FIRST FLOOR . Hall .. 1 1 2 3 Manager's Office . 2 1 1 1 5 13 Secretary's Office ..... 1 1 1 3 6 Consultation ...
Інші видання - Показати все
Загальні терміни та фрази
Age money Alternating Current ampère meter apparatus appliances arc lamps armature attached automatic baseframe bidder shall fill bids building c. p. lamps cables candle power capacity carried ceiling cent centre of distribution cleats conductors conduit connections contractor shall furnish cross-arms cuits cut-out boxes cut-outs and switches Direct Current double-pole dynamo or circuit dynamos Trade number erect the following fastened fill out completely fixture foundation(s full load fuses hand regulator incandescent lamps inches incombustible bases installation insulated wire insulation resistance junction boxes knife switch least lightning arresters main wires ments moisture moisture-proof molding necessary non-combustible number of lights number or designation ohms operation outlets pipes placed plant porcelain potential pressure proper protected pulleys purchaser Rating of exciters riser feeder schedule securely set screws shunt Sockets soldered spark arresters specification steam struction switchboard taps three-wire tightened tion tube two-wire voltage voltmeter volts walls waterproof wire smaller