Electric Lighting: A Practical Exposition of the Art, for the Use of Engineers, Students, and Others Interested in the Installation Or Operation of Electrical Plants, Том 2D. Van Nostrand Company, 1901 |
З цієї книги
Результати 1-5 із 51
Сторінка 24
... all of the lamps may be cut out , or they may be put upon two loops and none on the third , or the full load may be placed on a single loop , in which case the arrangement reduces to the ordinary one shown in Fig . 3 . When the number ...
... all of the lamps may be cut out , or they may be put upon two loops and none on the third , or the full load may be placed on a single loop , in which case the arrangement reduces to the ordinary one shown in Fig . 3 . When the number ...
Сторінка 47
... full load ; that is , when the maximum number of lamps are lighted . In fact , the circuits should be care- fully designed to approximate this condition as closely as practica- ble in most cases . When only a fraction of the lamps are ...
... full load ; that is , when the maximum number of lamps are lighted . In fact , the circuits should be care- fully designed to approximate this condition as closely as practica- ble in most cases . When only a fraction of the lamps are ...
Сторінка 48
... whole mains in Fig . 13. Even though all the lamps on one side were connected , and only one on the other side , the total drop and the difference between the voltage of lamps would be no greater than for the full - load conditions ...
... whole mains in Fig . 13. Even though all the lamps on one side were connected , and only one on the other side , the total drop and the difference between the voltage of lamps would be no greater than for the full - load conditions ...
Сторінка 49
... maximum as well as average drop are smaller with any load less than the full amount . The substitution of tapering mains for cylindrical ones makes the pressure still more uniform for fractional loads , since the drop is more nearly ...
... maximum as well as average drop are smaller with any load less than the full amount . The substitution of tapering mains for cylindrical ones makes the pressure still more uniform for fractional loads , since the drop is more nearly ...
Сторінка 51
... full load , since the total or average drop , and the greatest difference in voltage between lamps , will almost always be smaller for any number or arrangement of lamps less than the maximum load . Heretofore the principal point that ...
... full load , since the total or average drop , and the greatest difference in voltage between lamps , will almost always be smaller for any number or arrangement of lamps less than the maximum load . Heretofore the principal point that ...
Інші видання - Показати все
Electric Lighting: A Practical Exposition of the Art, for the Use of ... Francis Bacon Crocker Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
alternating current amperes apparatus arc lamps armature arrangement bulb bus bars cable candle-power capacity carbon cent circular mils conductors conduit connected constant current constant potential copper loss core cross-arm cross-section cut-out device diameter difference direct current distribution drop dynamo effect efficiency electric lighting electrical conductors employed energy equal fact feeders feeding-points filament flow frequency full load fuse globe ground heat hence incandescent lamps inch inclosed arc increase inductance insulation iron joint latter length less machines magnetic maximum mechanical metal meter method motor number of lamps ohms one-half open arc operation ordinary parallel phase pipe placed pole polyphase porcelain practically pressure primary produced reactance regulation represented in Fig resistance rheostat rotary rotary converters secondary circuit shown in Fig shunt side single-phase socket supplied switch temperature terminal three-phase three-wire system tion transformers tube two-phase two-wire two-wire circuit usually voltage volts wattmeter watts winding
Популярні уривки
Сторінка 460 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables.
Сторінка 11 - W, we find that the most economical area of conductor is that for which the annual cost of energy wasted is equal to the annual interest on that portion of the capital outlay which can be considered to be proportional to the weight of metal used. Professor George Forbes, in his Cantor Lecture, on " The Distribution of Electricity...
Сторінка 459 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.