Electric Lighting SpecificationsW. J. Johnstone Company, Limited, 1892 - 176 стор. |
З цієї книги
Результати 6-10 із 22
Сторінка 105
... FLOOR . Hall .. 1 1 2 3 Manager's Office . 2 1 1 1 5 13 Secretary's Office ..... 1 1 1 3 6 Consultation Room .. 1 1 2 5 Ete . LOCATION . Totals .. 4 1 2 1 2 : 1 1 12 122 27 LOCATION . No. of Fixtures Cat . No. No. of ELECTRIC LIGHTING ...
... FLOOR . Hall .. 1 1 2 3 Manager's Office . 2 1 1 1 5 13 Secretary's Office ..... 1 1 1 3 6 Consultation Room .. 1 1 2 5 Ete . LOCATION . Totals .. 4 1 2 1 2 : 1 1 12 122 27 LOCATION . No. of Fixtures Cat . No. No. of ELECTRIC LIGHTING ...
Сторінка 110
... floor line above the ground is foundation ( s ) shall be surmounted by ( a ) neat capstone ( s ) of upon which the engine ( s ) shall be placed . ( If capstones are not specified , each engine should be provided with an iron sub - base ...
... floor line above the ground is foundation ( s ) shall be surmounted by ( a ) neat capstone ( s ) of upon which the engine ( s ) shall be placed . ( If capstones are not specified , each engine should be provided with an iron sub - base ...
Сторінка 112
... floor stands , drop hangers , post hangers , pedestals , etc. complete with adjust- able , ( self - oiling ) boxes , base plates , bolts , etc. { Height } Height from Drop line of shaft Shafting to be ^ { S floor ceiling S to centre ...
... floor stands , drop hangers , post hangers , pedestals , etc. complete with adjust- able , ( self - oiling ) boxes , base plates , bolts , etc. { Height } Height from Drop line of shaft Shafting to be ^ { S floor ceiling S to centre ...
Сторінка 113
... floor timbers , wails , ceilings , posts , etc. ) horse - power . front boiler ( s ) ( each ) rated at 206. Boiler ( s ) . The boiler ( s ) shall contain not less than of effective heating surface and of grate area per rated horse ...
... floor timbers , wails , ceilings , posts , etc. ) horse - power . front boiler ( s ) ( each ) rated at 206. Boiler ( s ) . The boiler ( s ) shall contain not less than of effective heating surface and of grate area per rated horse ...
Сторінка 118
... floors or base frames , which must be kept filled to prevent absorption of moisture , and also kept clean and dry . 3. Not exposed to flying or combustible materials . 4. Each covered with a waterproof cover when not operating . In no ...
... floors or base frames , which must be kept filled to prevent absorption of moisture , and also kept clean and dry . 3. Not exposed to flying or combustible materials . 4. Each covered with a waterproof cover when not operating . In no ...
Інші видання - Показати все
Загальні терміни та фрази
Age money Alternating Current ampère meter apparatus appliances arc lamps armature attached automatic baseframe bidder shall fill bids building c. p. lamps cables candle power capacity carried ceiling cent centre of distribution cleats conductors conduit connections contractor shall furnish cross-arms cuits cut-out boxes cut-outs and switches Direct Current double-pole dynamo or circuit dynamos Trade number erect the following fastened fill out completely fixture foundation(s full load fuses hand regulator incandescent lamps inches incombustible bases installation insulated wire insulation resistance junction boxes knife switch least lightning arresters main wires ments moisture moisture-proof molding necessary non-combustible number of lights number or designation ohms operation outlets pipes placed plant porcelain potential pressure proper protected pulleys purchaser Rating of exciters riser feeder schedule securely set screws shunt Sockets soldered spark arresters specification steam struction switchboard taps three-wire tightened tion tube two-wire voltage voltmeter volts walls waterproof wire smaller