Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 6-10 із 42
Сторінка 22
... Connections on Second Floor . Scale 1⁄4 - inch to 1 foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends ...
... Connections on Second Floor . Scale 1⁄4 - inch to 1 foot . one that will almost always be required when drawings of the plumbing work are desired . That two stacks that pass up through tically , and as may readily be seen , these ends ...
Сторінка 30
... connection with them . The only requirements for making these views are the plans of the several floors O Lavatory 1 st . Floor Lavatory -Sink Wash Trays °° D 2nd Floor Attic Cellar 1st Floor 22 . Bath Room Elev- ation . such as are ...
... connection with them . The only requirements for making these views are the plans of the several floors O Lavatory 1 st . Floor Lavatory -Sink Wash Trays °° D 2nd Floor Attic Cellar 1st Floor 22 . Bath Room Elev- ation . such as are ...
Сторінка 33
... connection for the separate fixtures on the front elevation . In the bath room and kitchen the fix- tures come in front of each other , and if we should attempt on this small scale to show all the connections , the work would be so ...
... connection for the separate fixtures on the front elevation . In the bath room and kitchen the fix- tures come in front of each other , and if we should attempt on this small scale to show all the connections , the work would be so ...
Сторінка 36
... connection with Fig . 38 , to which we wish to call attention , is the manner in which the main line of back air for the bathroom stack is shown . In Fig . 34 of the previous article , it is shown directly in line with , and in front of ...
... connection with Fig . 38 , to which we wish to call attention , is the manner in which the main line of back air for the bathroom stack is shown . In Fig . 34 of the previous article , it is shown directly in line with , and in front of ...
Сторінка 43
... connections also . We think this a good idea for the reason that some of our positions , as seen from the side , and from the front . The front view of this fixture , will be found rather difficult to draw , and to make it as easy as ...
... connections also . We think this a good idea for the reason that some of our positions , as seen from the side , and from the front . The front view of this fixture , will be found rather difficult to draw , and to make it as easy as ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron