Storage Batteries Simplified, Operating Principles--care and Industrial Applications: A Complete, Non-technical But Authoritative Treatise Discussing the Development of the Modern Storage Battery, Outlining the Basic Operation of the Leading TypesNorman W. Henley publishing Company, 1917 - 196 стор. |
З цієї книги
Результати 6-10 із 59
Сторінка 52
... condition . Buckled plates are saucer- shaped , so that the old - fashioned square - cornered plates did the most chiseling with their corners . To minimize the effects of buckling , even though it be the result of abuse , U. S. L. ...
... condition . Buckled plates are saucer- shaped , so that the old - fashioned square - cornered plates did the most chiseling with their corners . To minimize the effects of buckling , even though it be the result of abuse , U. S. L. ...
Сторінка 56
... condition indicated by short capacity and a tendency to overheat when charging . Sometimes a deposit of sediment on the bottom of the cell will short circuit the plates . If the specific gravity is low and the plates have a whitish ...
... condition indicated by short capacity and a tendency to overheat when charging . Sometimes a deposit of sediment on the bottom of the cell will short circuit the plates . If the specific gravity is low and the plates have a whitish ...
Сторінка 57
... condition when dismantled , and in any case are exposed to the air during the cleaning process , and thus lose more or less of their charge . When reassembled , they consequently need a very complete charge , and in some cases the ...
... condition when dismantled , and in any case are exposed to the air during the cleaning process , and thus lose more or less of their charge . When reassembled , they consequently need a very complete charge , and in some cases the ...
Сторінка 58
... condition , until finally the plates become so sulphated that lack of capacity causes a complaint . This practice of adding electrolyte to cells . instead of water seems to be becoming more and more common . Sulphation , Cause and Cure ...
... condition , until finally the plates become so sulphated that lack of capacity causes a complaint . This practice of adding electrolyte to cells . instead of water seems to be becoming more and more common . Sulphation , Cause and Cure ...
Сторінка 59
... condition may be recognized in addition to the usual hydrometer readings . The common causes of plate deterioration are also given . The plates may be of poor color ; the color of a wet positive plate in good condition varies from a ...
... condition may be recognized in addition to the usual hydrometer readings . The common causes of plate deterioration are also given . The plates may be of poor color ; the color of a wet positive plate in good condition varies from a ...
Інші видання - Показати все
Загальні терміни та фрази
25 cents 50 cents A. A. HOUGHTON active material alkaline battery alternating current amperage ampere-hours amperes apparatus armature automobile boilers busbar cadmium capacity carbon charging rate chart chemical circuit coils Concrete condition connected connector construction device direct current dynamo edition electric electrolyte elements Exide flame flow fully charged fully illustrated grid heating hydrometer ignition system inches installation insulating lamps lathes lead plate lead-plate lighting Locomotive machine magnet manufacture mechanical metal method modern molds motor negative plate O'CONOR SLOANE operation outfit oxide PAGÉ plants plumbing positive plate pounds practical Price putty knife repair resistance Rheostat rubber sealing compound Sealing Nut shown at Fig shows specific gravity speed steam steel storage battery Storage Battery Company strap submarine sulphate sulphuric acid switch switchboard tank terminal posts tery tion treatise trouble tube Valve Gear vent voltage volts watt-hours wire wood separators zinc