... ceiling , the end of the gas pipe to extend beyond the surface of the plaster . ( Specify approximate number required . ) At the places located in the schedule and on the plans , meter outlets shall be run ( and a support for each meter ...
... ceiling , the end of the gas pipe to extend beyond the surface of the plaster . ( Specify approximate number required . ) At the places located in the schedule and on the plans , meter outlets shall be run ( and a support for each meter ...
Сторінка 84
... ceiling . Each pendant to be in length ( provided with a cord adjuster ) and protected by a double - pole ceiling cut - out . Both at the cut- out and in the socket the cord shall be knotted so that in no case will the weight come on ...
... ceiling . Each pendant to be in length ( provided with a cord adjuster ) and protected by a double - pole ceiling cut - out . Both at the cut- out and in the socket the cord shall be knotted so that in no case will the weight come on ...
Сторінка 87
... ceiling ( and provided with a suitable device for raising and lowering ) . On the exterior of ( the ) building ( s ) the lamps . specified shall be suspended from securely attached to - , ( and provided with a suita- ble device for ...
... ceiling ( and provided with a suitable device for raising and lowering ) . On the exterior of ( the ) building ( s ) the lamps . specified shall be suspended from securely attached to - , ( and provided with a suita- ble device for ...
Сторінка 91
... ceiling or wall . Tubes . All tubes shall be of sufficient size to allow 132. Sizes of the wires to be readily drawn in , withdrawn and reinserted at will . A quarter - inch tube will be permitted only where space is ex- tremely limited ...
... ceiling or wall . Tubes . All tubes shall be of sufficient size to allow 132. Sizes of the wires to be readily drawn in , withdrawn and reinserted at will . A quarter - inch tube will be permitted only where space is ex- tremely limited ...
Сторінка 104
... ceiling " outlets is important to the contractor , since the quan- tity both of labor and material required is often very largely dependent upon this rela- tion , which inay also determine the method of running the circuits , SWITCH ...
... ceiling " outlets is important to the contractor , since the quan- tity both of labor and material required is often very largely dependent upon this rela- tion , which inay also determine the method of running the circuits , SWITCH ...
Інші видання - Показати все
Загальні терміни та фрази
Alternating Current ampère meter ance apparatus appliances approved arc lamps armature attached automatic baseframe bids building c. p. lamps candle power capacity carried ceiling centre of distribution circuit cleats complete concealed conductors conduit connections contractor shall furnish covered cross-arms cuits cut-outs and switches device Direct Current double-pole efficient electric light engineer erect the following exciter fastened fixture floor foundation(s full load fuses galvanometer ground hand regulator incandescent lamps inches inclosed incombustible bases installation insulation joints junction boxes knife switch least lightning arresters Low Potential lug or set main wires ments metal moisture moisture-proof molding necessary non-combustible number of lights number or designation operation outlets placed plant porcelain proper protected pulleys purchaser Rating Risers Feeders schedule securely set screws shunt Sockets soldered spark arresters specification spirit and intent steam switchboard tests three-wire tightened tion tube two-wire voltmeter volts walls waterproof wire smaller
Популярні уривки
Сторінка 128 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Сторінка 124 - Must be provided with reliable stops to prevent carbons from falling out in case the clamps become loose.
Сторінка 122 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 134 - Must be so suspended that the entire weight of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or rosette, in order that the strain may be taken from the joints and binding screws.
Сторінка 138 - When current for light and power is taken from primary or secondary batteries, the same general regulations must be observed as apply to similar apparatus fed from dynamo generators developing the same difference of potential.
Сторінка 137 - Must be capable of being disconnected at the power plant, or of being divided into sections, so that, in case of fire on the railway route, the current may be shut off from...
Сторінка 120 - All multiple arc low potential systems (300 volts or less) must be provided with an indicating or detecting device, readily attachable, to afford easy means of testing where the station operates continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors.
Сторінка 121 - Service blocks must be covered over their entire surface with at least two coats of waterproof paint. c. Must be at least seven feet above the highest point of flat roofs, and at least one foot above the ridge of pitched roofs over which they pass or to which they are attached.
Сторінка 132 - ... b. Must always be placed in dry, accessible places, and be grouped as far as possible. Knife switches must be so placed that gravity will tend to open : rather than close the switch.
Сторінка 122 - Must be so placed that moisture cannot form a cross connection between them, not less than a foot apart, and not in contact with any substance other than their insulating supports.