... branch and a straight run of pipe . In this case , draw in the lines for the Y branch and the straight line , then connect these lines with the proper curve . Not until this is done should the hub on the branch or on the bend be drawn ...
... branch and a straight run of pipe . In this case , draw in the lines for the Y branch and the straight line , then connect these lines with the proper curve . Not until this is done should the hub on the branch or on the bend be drawn ...
Сторінка 32
... Fittings . the stack A. Therefore in the elevation , locate it at the same distance to the right of the stack as shown on page 31 . branch should run out straight for a little distance and 32 MECHANICAL DRAWING FOR PLUMBERS.
... Fittings . the stack A. Therefore in the elevation , locate it at the same distance to the right of the stack as shown on page 31 . branch should run out straight for a little distance and 32 MECHANICAL DRAWING FOR PLUMBERS.
Сторінка 33
... branch is actually a short one and not carried on a wide sweep , with the branch , but so far out as No. 2 shows . The depth of hubs should be about two- thirds the diameter of the pipe . The vented T - Y is shown in its correct form in ...
... branch is actually a short one and not carried on a wide sweep , with the branch , but so far out as No. 2 shows . The depth of hubs should be about two- thirds the diameter of the pipe . The vented T - Y is shown in its correct form in ...
Сторінка 34
... branch should run out straight for a little distance and not start to curve at once from the main part of the fitting . In Fig . 37 we give two exercises in draw- ing which combine the several fittings shown in the two preceding figures ...
... branch should run out straight for a little distance and not start to curve at once from the main part of the fitting . In Fig . 37 we give two exercises in draw- ing which combine the several fittings shown in the two preceding figures ...
Сторінка 37
... branch enters the vertical line of pipe just below the entrance of the waste from the sink , and that in doing so quite a wide sweep is made , the center for which is nearly an inch away . This we should draw in the following manner ...
... branch enters the vertical line of pipe just below the entrance of the waste from the sink , and that in doing so quite a wide sweep is made , the center for which is nearly an inch away . This we should draw in the following manner ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 50 cents A. A. HOUGHTON alternating current angle Architect's Scales automobile back air Bath Room boiler branch cellar plan CHAPTER complete COMPOUND LOCOMOTIVES Concrete connection construction contains COTTAGE HOUSE curves dotted drawn dynamos edition Electric eleva engravings fittings fixtures floor plans Fresh Air Inlet fully illustrated gas engine GASOLINE ENGINE give given hardening heating horizontal hubs Ignition Systems inch Kitchen Stack lathes Lavatory lines of pipe Locomotive machine main drain main trap main vent mechanical drawing method milling cutters modern molds motor O'CONOR SLOANE operation pantry sink perspective plain plumber practical treatise Price readers refrigerator represents roof Room Stack scale shading shown in Fig sketch Steam Engine steam turbines steel student tee square tion toilet room tractor triangle turbines types valuable Valve Gear vent line Walschaert Valve Gear Wash Trays water closet wiring