Mechanical Drawing for Plumbers: A Valuable and Practical Acquisition to the Plumber who Wishes to Gain a Thorough Knowledge of Drawing that Applies to His Particular Line of Plumbing WorkPlumber's Trade Journal Publishing Company, 1906 - 111 стор. |
З цієї книги
Результати 6-10 із 25
Сторінка 27
... branch and a straight run of pipe . In this case , draw in the lines for the Y branch and the straight line , then connect these lines with the proper curve . Not until this is done should the hub on the branch or on the bend be drawn ...
... branch and a straight run of pipe . In this case , draw in the lines for the Y branch and the straight line , then connect these lines with the proper curve . Not until this is done should the hub on the branch or on the bend be drawn ...
Сторінка 32
... Fittings . the stack A. Therefore in the elevation , locate it at the same distance to the right of the stack as shown on page 31 . branch should run out straight for a little distance and 32 38 MECHANICAL DRAWING FOR PLUMBERS.
... Fittings . the stack A. Therefore in the elevation , locate it at the same distance to the right of the stack as shown on page 31 . branch should run out straight for a little distance and 32 38 MECHANICAL DRAWING FOR PLUMBERS.
Сторінка 33
... branch is actually a short one and not carried on a wide sweep , with the branch , but so far out as No. 2 shows . The depth of hubs should be about two- thirds the diameter of the pipe . The vented T - Y is shown in its correct form in ...
... branch is actually a short one and not carried on a wide sweep , with the branch , but so far out as No. 2 shows . The depth of hubs should be about two- thirds the diameter of the pipe . The vented T - Y is shown in its correct form in ...
Сторінка 34
... branch should run out straight for a little distance and not start to curve at once from the main part of the fitting . In Fig . 37 we give two exercises in draw- ing which combine the several fittings shown in the two preceding figures ...
... branch should run out straight for a little distance and not start to curve at once from the main part of the fitting . In Fig . 37 we give two exercises in draw- ing which combine the several fittings shown in the two preceding figures ...
Сторінка 37
... branch enters the vertical line of pipe just below the entrance of the waste from the sink , and that in doing so quite a wide sweep is made , the center for which is nearly an inch away . This we should draw in the following manner ...
... branch enters the vertical line of pipe just below the entrance of the waste from the sink , and that in doing so quite a wide sweep is made , the center for which is nearly an inch away . This we should draw in the following manner ...
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva elevation shows ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory laying light lines of pipe main drain main line main stack main trap manner mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles Sanitary scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines student tee square thread tical tion top view triangle valve vertical lines Wash Trays waste water closet wrought iron
Популярні уривки
Сторінка 52 - Shade Lines. The light is assumed to come from the upper left hand corner of the drawing at an angle of 45 degrees to all horizontal and vertical lines.