Сторінка 73
... arrow C in Fig . 79 . A view taken at right angles to this would show one lavatory behind the other , and the result of such view would not be nearly as clear as the one given . In the view shown by Fig . 83 the Y branch into which the ...
... arrow C in Fig . 79 . A view taken at right angles to this would show one lavatory behind the other , and the result of such view would not be nearly as clear as the one given . In the view shown by Fig . 83 the Y branch into which the ...
Сторінка 74
... arrow B points in Fig . 80. Any other view of the work would show the fixtures one behind the other , and would make a very confused and in- distinct drawing . Kitchen Stack . Enlarged Dε- tail of Connec tion at Foot of Kitchen Stack ...
... arrow B points in Fig . 80. Any other view of the work would show the fixtures one behind the other , and would make a very confused and in- distinct drawing . Kitchen Stack . Enlarged Dε- tail of Connec tion at Foot of Kitchen Stack ...
Сторінка 78
... from the direction of the arrow E , which appears on both cellar and first floor plan . Instead of using up valuable space in showing floors above the first floor , and Bea Room Bea B Room Lavatory Lt Bed Room Bath 78 CHAPTER XVIII.
... from the direction of the arrow E , which appears on both cellar and first floor plan . Instead of using up valuable space in showing floors above the first floor , and Bea Room Bea B Room Lavatory Lt Bed Room Bath 78 CHAPTER XVIII.
Сторінка 80
... arrow F , which appears in the cellar and first floor plans . The reason for choosing this direction instead of one at right angles to it , is that in the latter the 4 - inch pipe under the cellar bottom , into which the hind the main ...
... arrow F , which appears in the cellar and first floor plans . The reason for choosing this direction instead of one at right angles to it , is that in the latter the 4 - inch pipe under the cellar bottom , into which the hind the main ...
Сторінка 82
... with Fig . 8 that we wish to bring out is the view which is obtained of the two lava- tory traps . The view of these two fix- tures is taken in the direction of the arrow " L " which shows in Figs . 3 82 CHAPTER XIX.
... with Fig . 8 that we wish to bring out is the view which is obtained of the two lava- tory traps . The view of these two fix- tures is taken in the direction of the arrow " L " which shows in Figs . 3 82 CHAPTER XIX.
Інші видання - Показати все
Загальні терміни та фрази
2nd Floor 3rd Floor 45 degrees appear arrow Attic Bath Room Stack Bed Room bend bibb Boiler branch Cellar Bottom cellar plan Cellar Wall chapter Cleanout COTTAGE HOUSE curves distance dotted lines drawn drip eleva ellipses figure fittings fixtures foot Fresh Air Inlet front elevation give given globe valve hubs illustrations inch incorrect sketch Kitchen Stack larger scale latter Lavatory lines of pipe main drain main line main stack main trap main Vent Line mechanical drawing necessary offset pantry sink parallel Partition pencil perspective plumber plumbing drawings plumbing system posi position practice Rain Leader readers refrigerator represents right angles scale drawings sectional view seen separate elevations shading shown in Fig side elevation sketch shows soil pipe space straight lines tee square thread tical tion Toilet Room Stack triangle valve vertical lines Wash Trays waste water closet wrought iron