Electric Lighting SpecificationsW. J. Johnstone Company, Limited, 1892 - 176 стор. |
З цієї книги
Результати 6-10 із 17
Сторінка 48
... Appliances . This contractor shall furnish and erect the following apparatus and material : ( Note . - In plants of any considerable size the switchboard specification is an extremely important one . Its general characteristics will be ...
... Appliances . This contractor shall furnish and erect the following apparatus and material : ( Note . - In plants of any considerable size the switchboard specification is an extremely important one . Its general characteristics will be ...
Сторінка 49
... appliances : main ampère meters . ampère meters for risers . dynamo galvanometers . dynamo galvanometer switches . dynamo switches . S riser { feeder } switches . switches for connecting system with dynamos in the building or with ...
... appliances : main ampère meters . ampère meters for risers . dynamo galvanometers . dynamo galvanometer switches . dynamo switches . S riser { feeder } switches . switches for connecting system with dynamos in the building or with ...
Сторінка 57
... - outs , and other appliances as are necessary for the nections . ༠ 07 42. Circuits . proper and convenient manipulation of ELECTRIC LIGHTING SPECIFICATIONS . 57 Summary Switchboard - Switchboard Apparatus and Connections.
... - outs , and other appliances as are necessary for the nections . ༠ 07 42. Circuits . proper and convenient manipulation of ELECTRIC LIGHTING SPECIFICATIONS . 57 Summary Switchboard - Switchboard Apparatus and Connections.
Сторінка 58
... appliances to be named by each bidder in his proposal . For systems operating dynamos and circuits in parallel , the appli- ances and connections shall be such as will permit adding to or taking from the circuit . any dynamo without in ...
... appliances to be named by each bidder in his proposal . For systems operating dynamos and circuits in parallel , the appli- ances and connections shall be such as will permit adding to or taking from the circuit . any dynamo without in ...
Сторінка 63
... appliances as are necessary for the proper and convenient manipulation of the circuits , such appliances to be named by each bidder in his proposal . The appliances and connections shall be such as will permit the operation of any ...
... appliances as are necessary for the proper and convenient manipulation of the circuits , such appliances to be named by each bidder in his proposal . The appliances and connections shall be such as will permit the operation of any ...
Інші видання - Показати все
Загальні терміни та фрази
Age money Alternating Current ampère meter apparatus appliances arc lamps armature attached automatic baseframe bidder shall fill bids building c. p. lamps cables candle power capacity carried ceiling cent centre of distribution cleats conductors conduit connections contractor shall furnish cross-arms cuits cut-out boxes cut-outs and switches Direct Current double-pole dynamo or circuit dynamos Trade number erect the following fastened fill out completely fixture foundation(s full load fuses hand regulator incandescent lamps inches incombustible bases installation insulated wire insulation resistance junction boxes knife switch least lightning arresters main wires ments moisture moisture-proof molding necessary non-combustible number of lights number or designation ohms operation outlets pipes placed plant porcelain potential pressure proper protected pulleys purchaser Rating of exciters riser feeder schedule securely set screws shunt Sockets soldered spark arresters specification steam struction switchboard taps three-wire tightened tion tube two-wire voltage voltmeter volts walls waterproof wire smaller