Storage Batteries Simplified, Operating Principles--care and Industrial Applications: A Complete, Non-technical But Authoritative Treatise Discussing the Development of the Modern Storage Battery, Outlining the Basic Operation of the Leading TypesNorman W. Henley publishing Company, 1917 - 196 стор. |
З цієї книги
Результати 11-15 із 46
Сторінка 49
... BOTTOM [ WELDED TO SIDES ] Fig . 18. - Part Sectional View of Edison Alkaline Battery , Showing Internal Arrangement of Plates and Relation of Principal Parts to Each Other . cold - rolled steel , which is thoroughly welded at.
... BOTTOM [ WELDED TO SIDES ] Fig . 18. - Part Sectional View of Edison Alkaline Battery , Showing Internal Arrangement of Plates and Relation of Principal Parts to Each Other . cold - rolled steel , which is thoroughly welded at.
Сторінка 50
... Edison cell parts is clearly out- lined at Fig . 18 ; the plate construction is depicted at Fig . 19 , as well as the tubes . from the positive plate and pockets used in the negatives . Function of Separator . - Separators are necessary ...
... Edison cell parts is clearly out- lined at Fig . 18 ; the plate construction is depicted at Fig . 19 , as well as the tubes . from the positive plate and pockets used in the negatives . Function of Separator . - Separators are necessary ...
Сторінка 51
... Positive Tube Alkaline Battery . a separator affords the opportunity for ' treeing ' across. Fig . 19. - Positive and Negative Plates Used in the Edison Fig . 24. - Automatic Filler for Renewing Water Supply. FUNCTION OF SEPARATOR 51.
... Positive Tube Alkaline Battery . a separator affords the opportunity for ' treeing ' across. Fig . 19. - Positive and Negative Plates Used in the Edison Fig . 24. - Automatic Filler for Renewing Water Supply. FUNCTION OF SEPARATOR 51.
Сторінка 53
... Edison Cell - Tools and Supplies for Repairing - Taking Down Exide Batteries - Taking Down Gould Sealed Cells - Disassembling Willard Battery - Lead - Burning Ap- paratus -- Lead - Burning Process -- Battery Defects and Restoration Sum ...
... Edison Cell - Tools and Supplies for Repairing - Taking Down Exide Batteries - Taking Down Gould Sealed Cells - Disassembling Willard Battery - Lead - Burning Ap- paratus -- Lead - Burning Process -- Battery Defects and Restoration Sum ...
Сторінка 66
... Edison bat- tery , which is entirely different in construction . The Edison cell uses an electrolyte consisting of 21 % solution of potash in dis- tilled water so that the electrolyte is alkaline instead of acidulous . For 6 - volt ...
... Edison bat- tery , which is entirely different in construction . The Edison cell uses an electrolyte consisting of 21 % solution of potash in dis- tilled water so that the electrolyte is alkaline instead of acidulous . For 6 - volt ...
Інші видання - Показати все
Загальні терміни та фрази
25 cents 50 cents A. A. HOUGHTON active material alkaline battery alternating current amperage ampere-hours amperes apparatus armature automobile boilers busbar cadmium capacity carbon charging rate chart chemical circuit coils Concrete condition connected connector construction device direct current dynamo edition electric electrolyte elements Exide flame flow fully charged fully illustrated grid heating hydrometer ignition system inches installation insulating lamps lathes lead plate lead-plate lighting Locomotive machine magnet manufacture mechanical metal method modern molds motor negative plate O'CONOR SLOANE operation outfit oxide PAGÉ plants plumbing positive plate pounds practical Price putty knife repair resistance Rheostat rubber sealing compound Sealing Nut shown at Fig shows specific gravity speed steam steel storage battery Storage Battery Company strap submarine sulphate sulphuric acid switch switchboard tank terminal posts tery tion treatise trouble tube Valve Gear vent voltage volts watt-hours wire wood separators zinc