and on the plans, meter outlets shall be run (and a support for each meter provided consisting of securely fastened to the wall). Each elevator is to be provided with 99, Elevator c. p. lamp(s). Each elevator shall be on its own cut-out and circuit which shall be run from the distribution box at (location). The wiring shall include the wiring of the elevator car, all necessary cables and the connection with its outlet. The cables shall be well in sulated, flexible and properly protected from abrasion. Lights. The molding used in the places speci- 100. Molding. fied above shall be of and finished On all outside walls, bare brick or stone walls, etc., it shall consist of a backing and capping. and Deductions. While the schedule is intended to rep- 101. Additions resent very closely the number of lights 102. Instruction. and outlets to be wired to, yet, as some changes may become necessary during the process of construction, each bidder shall name in his proposal a price to be added to or deducted from the contract price for each light or outlet wired for in excess of the number specified, or which shall be cancelled, provided such addition or cancellation involves no change in the work already completed and shall be along the lines of existing circuits. (Note. It may be desirable that the purchaser furnish one man to work under the contractor in order that he may have a man thoroughly familiar with all the details of the construction; the contractor to give such instruction as will enable him to acquire a thorough and intelligent knowledge of methods, appliances, location of circuits, etc.) 103 Hanging (Note.-To be inserted if this contract of Fixtures. or is to complete the wiring, including the attachment of lamps and sockets.) This contractor shall hang all fixtures, including the assembling and wiring of the fixtures (unless provided for under Fixtures), the attaching of sockets, lamps and shades, and the connection with the ends of the taps. Insulating joints will be furnished, where required, by the fixture contractor but this contractor shall furnish and connect a suitable cut-out for each outlet, protecting both sides of the circuit. This contractor shall attach -sockets by means of a (suitable gas attachment) to the (gas) fixtures already in place. These fixtures shall be properly insulated and shall be wired in the following with At each outlet a suitable cut-out shall be provided protecting both sides of the circuit. In each socket the proper lamp shall be placed and all shades shall be attached. manner: Sockets and lamps shall be suspended by means of pendants from the ceil 104. Wiring and Attaching Sockets to Fixtures Place. already in 105. Suspen and Lamps. sion of Sockets ing. Each pendant to be in length, Three-Wire System. This specification is identical with the two-wire specification, except in "System," p. 94, sec. 84, in place of which insert the following: All risers and mains shall be fig- 106. System. ured on the basis of the three-wire sys- |