Mechanical Drawing for Plumbers: A Concise, Comprehensive and Practical Treatise on the Subject of Mechanical Drawing, in Its Various Modern Applications to the Work of All who are in Any Way Connected with the Plumbing Trade |
З цієї книги
Сторінка 27
In this case , draw in the lines for the Y branch and the straight line , then connect
these lines with the proper curve . Not until this is done should the hub on the
branch or on the bend be drawn . Now with reference to NO 3 . NO 4 . FIG . 29 .
In this case , draw in the lines for the Y branch and the straight line , then connect
these lines with the proper curve . Not until this is done should the hub on the
branch or on the bend be drawn . Now with reference to NO 3 . NO 4 . FIG . 29 .
Сторінка 64
... of waste to the point where it more space than we wish to devote čo enters the
horizontal line on the cellar them , and then again , by reference to the cellar plan
, a perfectly clear idea can be an 64 MECHANICAL DRAWING FOR PLUMBERS.
... of waste to the point where it more space than we wish to devote čo enters the
horizontal line on the cellar them , and then again , by reference to the cellar plan
, a perfectly clear idea can be an 64 MECHANICAL DRAWING FOR PLUMBERS.
Сторінка 92
This is not a necessity by any means , but a reference to Figs . 112 and 113 will
convince the reader , we believe , that it sets off a drawing to quite an extent , and
adds to its appearance . Likewise , the section lines of the division wall shown in
...
This is not a necessity by any means , but a reference to Figs . 112 and 113 will
convince the reader , we believe , that it sets off a drawing to quite an extent , and
adds to its appearance . Likewise , the section lines of the division wall shown in
...
Сторінка 93
Partition main Vent conrrecte into main Slack . 3ra Floor Plumbing on 2nd f100 -
same ao on 3rd floor TATIZITE 1st Floor Back Air Pipe P11 us mois 27 main Vent
Ducted into main Stack FIG . 112 . CHAPTER XXII S will be seen by reference to
...
Partition main Vent conrrecte into main Slack . 3ra Floor Plumbing on 2nd f100 -
same ao on 3rd floor TATIZITE 1st Floor Back Air Pipe P11 us mois 27 main Vent
Ducted into main Stack FIG . 112 . CHAPTER XXII S will be seen by reference to
...
Сторінка 94
CHAPTER XXII S will be seen by reference to the All modern ordinances prohibit
direct floor plan of the six - flat depart - connection of the refrigerator with the ment
building shown in tứe drainago system , and reference to our last chapter ...
CHAPTER XXII S will be seen by reference to the All modern ordinances prohibit
direct floor plan of the six - flat depart - connection of the refrigerator with the ment
building shown in tứe drainago system , and reference to our last chapter ...
Відгуки відвідувачів - Написати рецензію
Не знайдено жодних рецензій.
Інші видання - Показати все
Загальні терміни та фрази
angle appear applied automobile bath boiler branch building cellar cents CHAPTER clear clearly closet complete Concrete connection construction contains covered curves described desired direction drawing drawn edition Electric elevation engine explained fact figure fittings fixtures floor plans front Gasoline Gear give given heating illustrated inch kinds kitchen lathes light lines Locomotive looking machine manner matter mechanical method molds motor necessary obtained operation perspective pipe plain plumber plumbing position practical present Price published questions readers reference represents roof rules scale seen shading shown shown in Fig side simple sink sketch space square stack steam steel student tables taken thing tion trap treated treatise triangle troubles types usually valuable valve various vent