" ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material. "
Standard Tables for Electric Wiremen: With Instructions for Wiremen and ... - Сторінка 71
автори: Charles M. Davis - 1893 - 128 стор.
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...Must be separated at least six inches. (6) Must be provided with an approved waterproof covering. (e) Must be carefully put up. (d) Must be supported by...Interior Conduits : * (a) Must be continuous from one junction box to another, or to fixtures, and must be of material that will resist the fusion of the...
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 стор.
...insulation, except where used for pendants, conductors — (a) Must be separated at least six inches. (&) Must be provided with an approved waterproof covering....gases or dust, or to flyings of combustible material. (a) Must be protected when passing through floors, walls, partitions, timbers, etc., by waterproof,...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...'separated at least six inches. b. Must be provided with an approved waterproof covering. (See Definitions). c. Must be carefully put up. d. Must be supported...such as glass or porcelain. 22. INTERIOR CONDUITS*: — (See Definitions). a. Must be continuous from one junction box to another, or to fixtures, and...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...at least six inches. b. Must be provided with an approved water-proof covering. (See Definitions.) c. Must be carefully put up. d. Must be supported...such as glass or porcelain. 22. INTERIOR CONDUITS* : (See Definitions.) a. Must be continuous from one junction box to another, or to fixtures, and must...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...chemical compounds or mixtures as it will be liable to be subjected to in the risk under consideration.] c. Must be carefully put up. d. Must be supported...partitions, timbers, etc., by waterproof, non-combustible, insulating-tubes, such as glass or porcelain. The requirements stated under Rule 21 are, it will be...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...at least six inches, b. Must be provided with an approved water-proof covering. (See Definitions.) c. Must be carefully put up. d Must be supported by...through floors, walls, partitions, timbers, etc., by water- proof, non-combustible, insulating tubes, such as glass or porcelain. DEFINITIONS. RULE 21....
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...provided with an approved waterproof covering. (See Definitions). c. Must be carefully put up. celain insulators. No switches or fusible cut-outs will be...insulating tubes, such as glass or porcelain. 22. INTERIOR CONDUITS*:—(See • Definitions). a. Must be continuous from one junction box to another, or to fixtures,...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...chemical compounds or mixtures as it will be liable to be subjected to in the risk under consideration. c. Must be carefully put up. d. Must be supported by glass or porcelain insulators. No switches, key sockets or fusible cut-outs will be allowed where exposed to inflammable gases or dust, or to flyings...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...at least six inches. b. Must be provided with an approved water-proof covering. (See Definitions.) c. Must be carefully put up. d. Must be supported by glass or porcelain insulators. Nc switches or fusible cut-outs will be allowed where exposed to inflammable gases or dust, or to flyings...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...switch or circuit breaker. b. Must not be placed in the immediate vicinity of easily ignitable stuff or where exposed to inflammable gases or dust or to flyings of combustible material. c. Must, when exposed to dampness, either be inclosed in a waterproof box or mounted on porcelain knobs....
Повний перегляд - Докладніше про цю книгу