" Must each be provided with a name-plate, giving the maker's name, the capacity in volts and amperes, and the normal speed in revolutions per minute. "
Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ... - Сторінка 59
автори: Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 329 стор.
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...their frames insulated from their bed-plates. c. Must each be provided with a waterproof cover. d. Must each be provided with a name-plate, giving the maker's name, the capacity in voltage and amperes and normal speed in revolutions per minute. 61. WIRES— a. Must have an approved...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 514 стор.
...their frames insulated from their bed-plates. c. Must each be provided with a waterproof cover. d. Must each be provided with a name-plate, giving the maker's name, the capacity in voltage and amperes and normal speed in revolutions per minute. 69. Wires — The insulation for all...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...jurisdiction may, in writing, modify the requirements. e. Must each be provided with a waterproof cover. f. Must each be provided with a name-plate, giving the maker's name, the capacity iu volts and amperes, and the normal speed in revolutions per minute. :J. Conductors — From generators...
Повний перегляд - Докладніше про цю книгу

Agents' and Inspectators Pocket-book of Fire Protection

George Velten Steeb - 1902 - 230 стор.
...dry place, have their frames insulated from their bed-plates, be provided with waterproof covers and be provided with a name-plate giving the maker's name, the capacity in voltage and amperes and normal speed in revolutions per minute. Wires must be supported in approved...
Повний перегляд - Докладніше про цю книгу

Electric Lighting ...

Francis Bacon Crocker - 1904 - 696 стор.
...jurisdiction may, in writing, modify the requirements. e. Must each be provided with a waterproof cover. /. Must each be provided with a name-plate, giving the...maker's name, the capacity in volts and amperes, and the normal-speed in revolutions per minute. 2. Conductors — From generators to switchboards, rheostats,...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906 - 528 стор.
...power when it is most needed, and for an indefinite length of time. Name-Plates. Every dynamo should be provided with a name-plate, giving the maker's name, the capacity in volts ami amperes, and the normal speed in revolutions per minute. This will show exactly what the machine...
Повний перегляд - Докладніше про цю книгу

Report of the Commissioner of Corporations on Transportation by Water in the ...

United States. Bureau of Corporations - 1909 - 648 стор.
...their frames insulated from their bed-plates. (c) Must each be provided with a water-proof cover. (d) Must each be provided with a name-plate, giving the maker's name, the capacity in voltage and amperes and normal speed in revolutions per minute. (2) Wires. — (a) Must be supported...
Повний перегляд - Докладніше про цю книгу

Building, Plumbing, Gas and Electrical Laws of the City of Dallas, Texas ...

Dallas (Tex.). - 1914 - 266 стор.
...insulated hooks, or else there must be an insulator interposed between the motor and its support. (v) Must each be provided with a name-plate, giving the maker's name, the normal capacity in volts and amperes and the normal speed in revolutions per minute. (w) Terminal blocks,...
Повний перегляд - Докладніше про цю книгу

Reports of Decisions of the Public Service Commission, First District ..., Том 7

New York (State). Public Service Commission. First District - 1917 - 452 стор.
...bushings or their equivalent, shall be used. Synchronous Converters (a) Synchronous converters shall each be provided with a nameplate, giving the maker's name, the capacity in kilowatts, the volts and amperes, and the normal speed in revolutions per minute. (b) Synchronous converters...
Повний перегляд - Докладніше про цю книгу

Report, Том 1

New York (State). Public Service Commission. First District - 1918 - 792 стор.
...converters shall be grounded in accordance with the rules for grounding. (a) Synchronous converters shall each be provided with a name-plate, giving the maker's name, the capacity in kilowatts, the volts and amperes, and the normal speed in revolutions per minute. (c) Synchronous converters...