| Arthur Eugene Watson - 1892 - 118 стор.
...37. A cnt-out must be placed where the underground or overhead service joins the inside wires, and at every point where a change is made in the size...the larger wire is intended to protect the smaller). 38. Cut-outs, switches, and other devices which occasion a break in the circuit, must be so arranged... | |
| Frank Eugene Kidder - 1892 - 1032 стор.
...: (a) Must be in plain sight or enclosed in an approved box, readily accessible. (6) Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). (el Must be supported on bases of non-combustible, insulating, moisture-proof... | |
| National Electric Light Association. Convention - 1892 - 458 стор.
...where the overhead or underground conductors enter a building and join the inside wires. 2. Placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). This includes all flexible conductors. All such junctions must be in plain... | |
| La Motte C. Atwood - 1893 - 180 стор.
...carry. 37. A cut-out must be placed where the underground or overhead sendee joins the inside wires, and at every point where a change is made in the size of the wire (unless the cut-out in the larger wire be intended to protect the smaller). 38. Cut-outs, switches, and other devices which occasion a break... | |
| Charles M. Davis - 1893 - 162 стор.
...CUT-OUTS— a. Must be in plain sight or enclosed in an approved box, readily accessible. b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of noncombustible, insulating, moisture-proof... | |
| 1894 - 622 стор.
...the overhead or underground conductors enter a building and join the inside wires. 2. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). This includes all flexible conductora. All euch junctions must be In plain... | |
| Arthur Vaughan Abbott - 1895 - 646 стор.
...the overhead or underground conductors enter a building and join the inside wires. 2. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). This includes all flexible conductors. All such junctions must be in plain... | |
| Richard Henry Pierce - 1896 - 234 стор.
...plain sight or enclosed in an approved box, readily accessible. (See Definitions), b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller), c. Must be supported on bases of non-combustible, insulating, moisture-proof... | |
| Earle Abbott Merrilol - 1896 - 232 стор.
...plain sight or enclosed in an approved box readily accessible. (See Definitions). b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of non-combustible, insulating, moistureproof... | |
| George H. Kimber - 1896 - 80 стор.
...melted fuse metal coming in contact with any substance which might be ignited thereby. b. Must be placed at every point where a change is made in the size of the wire (unless the cut-out in the larger wire will protect the smaller). c. Must be supported on bases of non-combustible, insulating, moisture-proof... | |
| |