Сховані поля
Книги Книги
" Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule... "
Electric Lighting Specifications for the Use of Engineers and Architects - Сторінка 140
автори: Earle Abbott Merrill - 1892 - 176 стор.
Повний перегляд - Докладніше про цю книгу

Telegraphic Journal and Monthly Illustrated Review of Electrical Science, Том 8

1891 - 680 стор.
...the poles immediately outside the trolley wire. 3. Capable of being disconnected at the power-house, or of being divided into sections, so that in case...protected against contact with all other conductors. CAR WIRINO. All wires in cars must be run out of reach of the passengers, and shall be insulated with a...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 620 стор.
...bring disconnected at the power house, or of being divided into sections, so that, in case of flre on the railway route, the current may be shut off...particular section and not interfere with the work of the flreraen in extinguishing the flames. This rule also applies to feeders. 4. Must be safely protected...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...outside the trolley wire. 3. Must be capable of being disconnected at the power-house, or of beingdivided into sections, so that, in case of fire on the railway...the flames. This rule also applies to feeders. 4. Must be safely protected against contact with all other conductors. 152. CAR-WIRING. All wires in cars...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...supports shall also be insulated from the poles immediately outside of the trolley wire. c. Must be capable of being disconnected at the power house,...section, and not interfere with the work of the firemen. This rule also applies to feeders. d. Must be safely protected against contact with all other conductors....
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...supports shall also be insulated from the poles immediately outside of the trolley wire. c. Must be capable of being disconnected at the power house,...section and not interfere with the work of the firemen. This rule also applies to feeders. d. Must be safely protected against contact with all other conductors....
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...supports shall also be insulated from the poles immediately outside of the trolley wire. c. Must be capable of being disconnected at the power house....section and not interfere with the work of the firemen. This rule also applies to feeders. d Must be safely protected against contact with all other conductors....
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...immediately outside of the trolley-wire. c. Must be capable of being disconnected at the powerhouse, or of being divided into sections, so that in case...section and not interfere with the work of the firemen. This rule also applies to feeders. d. Must be safely protected against contact with all other conductors....
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 708 стор.
...will be considered as one insulation. /. Must be capable of being disconnected at the power plant, or of being divided into sections, so that, in case...section and not interfere with the work of the firemen. This rule also applies to feeders. m. Must be safely protected against accidental contact where crossed...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...will be considered as one insulation. I. Must be capable of being disconnected at the power plant, or of being divided into sections, so that, in case...section and not interfere with the work of the firemen. This rule also applies to feeders. m. Must be safely protected against accidental contact where crossed...
Повний перегляд - Докладніше про цю книгу

Electric Lighting: A Practical Exposition of the Art, for the Use of ..., Том 2

Francis Bacon Crocker - 1901 - 528 стор.
...will be considered as one insulation. /. Must be capable of being disconnected at the power plant, or of being divided into sections, so that, in case...section and not interfere with the work of the firemen. This rule also applies to feeders. m. Must be safely protected against accidental contact where crossed...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF