Пошук Зображення Карти Play YouTube Новини Gmail Диск Більше »
Увійти
Книги Книги
" The wiring in any building must test free from grounds; ie, the complete installation must have an insulation between conductors and between all conductors and the ground (not including attachments, sockets, receptacles, etc.) not less than that given... "
Carpentry and Contracting: A Practical Reference Work on Carpentry, Building ... - Сторінка 382
1919
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...shall have an insulation resistance of at least 25,000 ohms, and should have an insulation resistance between conductors and between all conductors and...including attachments, sockets, receptacles, etc.) of not less than the following : Up to 10 amperes 4.000,000 1,000,000 K0fl,0(!0 60 100 900 400 800...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...shall have an insulation resistance of at least 25,000 ohms, and should have an insulation resistance between conductors and between all conductors and...including attachments, sockets, receptacles, etc.), of not less than the following:— Up to 10 amperes 25 50 100 200 400 800 1600 4,000,000 1,600,000...
Повний перегляд - Докладніше про цю книгу

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 стор.
...resistance of at least 1oo,ooo ohms and the whole installation should have an insulation resistance between conductors and between all conductors and...including attachments, sockets, receptacles, etc.) of not less than the following : Up to IG amperes. .- 4,000,000 25 ' 1,6oo.coo 50 " 800,000 100 300,000...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...shall have an insulation resistance of at least 25,000 ohms, and should have an insulation resistance between conductors and between all conductors and...including attachments, sockets, receptacles, etc.), of not less than the following: — UP to 10 amperes 4,000,000 as 50 100 200 400 800 1600 1,600,000...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...shall have an insulation resistance of at least 25,000 ohms, and should have an insulation resistance between conductors and between all conductors and...including attachments, sockets, receptacles, etc.), of not less than the following : — Up to 10 amperes 4,000,000 " " 25 " 1,600,000 " " 50 " 800,000...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...shall have an insulation resistance of at least 25,000 ohms, and should have an insulation resistance between conductors and between all conductors and...including attachments, sockets, receptacles, etc.) of not less than the following : All cut-outs and safety devices in place in the above. Where lamp...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 стор.
...Resistance.— The wiring in any building must test free from grounds, i. t , the complete installation between conductors and between all conductors and...including attachments, sockets, receptacles, etc.) of not less than the following : Up to 5 amperes 4 000,000 2.000,000 25 SO loo voo 4 'JO 8 o 1,600...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1120 стор.
...moving parts. CLASS E. MISCELLANEOUS. 56. INSULATION RESISTANCE — The wiring in any building must test free from grounds., ie, the complete installation...including attachments, sockets, receptacles, etc.) of not less than the following : Up to 5 amperes 4,000,000 10 " 2,000,000 25 " 800,000 " 50 " 400,000...
Повний перегляд - Докладніше про цю книгу

Electric Lighting: A Practical Exposition of the Art, for the Use of ..., Том 2

Francis Bacon Crocker - 1901 - 528 стор.
...free from connection with each other. 66. Insulation Resistance — The wiring in any building must test free from grounds; ie, the complete installation...and the ground (not including attachments, sockets, recepticles, etc.) of not less than the following : Up to 5 amperes 4,000,001) ohms. 10 25 50 | 200...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...free from connection with each, other. GO. insulation iSr* illume**. The wiring in any building must test free from grounds ; ie, the complete installation...and the ground (not including attachments, sockets, recep-. Uicles, etc.) of not less than the following : Up to All cutouts and safety devices in place...