Сторінка 15
... less apparent but no less essential considera- tions present themselves in the practical aspects of the ground . In rocky or hilly country , besides the significance of the outlook , is the importance of placing the house so that ...
... less apparent but no less essential considera- tions present themselves in the practical aspects of the ground . In rocky or hilly country , besides the significance of the outlook , is the importance of placing the house so that ...
Сторінка 30
... less than 30 minutes . To test for soundness , mix some cement with a little water in several pats about inch thick and 3 inches in diameter , running to a thin edge . After these pats have been kept under a damp cloth for about 24 ...
... less than 30 minutes . To test for soundness , mix some cement with a little water in several pats about inch thick and 3 inches in diameter , running to a thin edge . After these pats have been kept under a damp cloth for about 24 ...
Сторінка 31
... not , as they will rock and jar when struck with the rod if not thoroughly bedded . No stone should be set with a depth from the face of less than 6 inches , and all stones should be laid so that 31 BUILDING SUPERINTENDENCE 21.
... not , as they will rock and jar when struck with the rod if not thoroughly bedded . No stone should be set with a depth from the face of less than 6 inches , and all stones should be laid so that 31 BUILDING SUPERINTENDENCE 21.
Сторінка 32
... less carefully worked into the seams . This kind of work is easily de- tected by use of the steel rod , which we can feel mov- ing the stones if they are Lu poorly bedded . The right way is to settle each stone , Fig . 17. Careless Wall ...
... less carefully worked into the seams . This kind of work is easily de- tected by use of the steel rod , which we can feel mov- ing the stones if they are Lu poorly bedded . The right way is to settle each stone , Fig . 17. Careless Wall ...
Сторінка 35
... less room and are more easily and quickly placed . For ordinary cellar work , there are in the market columns made of wrought - iron pipes , filled with a carefully pre- pared cement concrete , which cost less than brick piers . These ...
... less room and are more easily and quickly placed . For ordinary cellar work , there are in the market columns made of wrought - iron pipes , filled with a carefully pre- pared cement concrete , which cost less than brick piers . These ...
Інші видання - Показати все
Carpentry and Contracting: A Practical Reference Work on Carpentry ..., Том 3 American Technical Society Попередній перегляд недоступний - 2016 |
Carpentry and Contracting; a Practical Reference Work on Carpentry ..., Том 3 American Technical Society Попередній перегляд недоступний - 2013 |
Загальні терміни та фрази
alternating current amperes arc lamps arch architect ashlar boards brick building cable carefully ceiling cellar cement chimney circuit breakers coat coil columns concrete conductors conduit connected construction copper cord covered danger devices direct current door electric feet finish fire fireproof fixtures floor beams flush frame fuses girders glass ground hazard heat heater incandescent lamps inches inside installed insulation iron joints joists Knife Switches laid lamps light lime lines material metal lathing method molding mortar motor nails necessary ordinary outlet painted partitions pipes plaster plate porcelain Portland cement protection resistance rheostats roof rubber sand sashes screws secured shellac shingles shown in Fig shows side slate sockets soldered space steel stone studs superintendent supply surface switch terra cotta thickness tiles timbers tion transformer tubing usually voltage voltmeter volts wall window wires wood wooden
Популярні уривки
Сторінка 382 - The wiring in any building must test free from grounds; ie, the complete installation must have an insulation between conductors and between all conductors and the ground (not including attachments, sockets, receptacles, etc.) not less than that given...
Сторінка 373 - ... be thoroughly ventilated to the outdoor air, if possible, through a chimney or flue. There should be at least six inches air space on all sides of the transformer.
Сторінка 152 - ... along the surface where the junction is to be made and the surface thoroughly wet. The bond and other arrangements will depend upon the circumstances of the case. The surfaces connected should be fitted as accurately as practicable, so that by using but little mortar no disunion may take place from settling. As a rule, it is better that new work should butt against the old, either with a straight joint visible on the face, or let into a chase, sometimes called a
Сторінка 307 - Must be placed at every point where a change Is made in the size of wire (unless the cut-out In the larger wire will protect the smaller.) (c) Must be in plain sight, or enclosed in an approved cabinet, and readily accessible.
Сторінка 152 - ... so that the straight joint may not show ; but if it is necessary to bond them together the new work should be built in a quick-setting cement mortar and each part of it allowed to set before being loaded. In pointing old masonry all the decayed mortar must be completely raked out with a hooked iron point and the surfaces well wetted before the fresh mortar is applied.
Сторінка 350 - Cables may be supported in approved junction boxes on two or more insulating supports so placed that the conductors will be deflected at an angle of not less than 90 degrees, and carried a distance of not less than twice the diameter of the cable from its vertical position. Cables so suspended may be additionally secured to these insulators by tie wires.
Сторінка 96 - ... due to the difference in temperature. When water is heated it expands, and thus a given volume becomes lighter and tends to rise, and the cooler water flows in to take its place; if the application of heat is kept up, the circulation thus produced is continuous. The velocity of flow "depends upon the difference in temperature between the supply and return, and the height of the radiator above the boiler.
Сторінка 371 - Any circuit attached to any machine, or combination of machines, which develops a difference of potential, between any two wires, of over ten volts and less than 300 volts, shall be considered as a low-potential circuit...
Сторінка 144 - ... (sand and rubbish are often substituted for bricks), allowing them to find their own bearing; when the trough is filled, it is plastered over with stiff mortar, and the header course laid and the operation repeated. This practice may have some advantage in celerity in executing work, but none in strength or security.
Сторінка 4 - A Dictionary of Architecture and Building," and "How to Judge Architecture." ADF HAMLIN, AM Professor of Architecture at Columbia University. Author of "A Text-book of the History of Architecture. RALPH ADAMS CRAM Architect Author of "Church Building." CH MOORE Author of " Development and Character of Gothic Architecture." ROLLA C. CARPENTER, CE, MME Professor of Experimental Engineering. Cornell University. Author of " Heating and Ventilating Buildings.