| American Institute of Electrical Engineers - 1897 - 710 стор.
...Special attention is directed to the rules for rooms where acid fumes exist. (See No. 24. j and k.} d. All secondary batteries must be mounted on non-absorptive,...glass, or thoroughly vitrified and glazed porcelain. t. The use of any metal liable to corrosion, must be avoided in connections of secondary batteries.... | |
| American Society of Mechanical Engineers - 1898 - 1122 стор.
...Special attention is directed to the rules for rooms where acid fumes exist. (See No. 24, j. and k.) d. All secondary batteries must be mounted on non-absorptive,...glass or thoroughly vitrified and glazed porcelain. e. The use of any metal liable to corrosion must be avoided in connections of secondary batteries.... | |
| Horatio Alvah Foster - 1901 - 1018 стор.
...Special attention is directed to the rules for rooms where acid fumes exist (see No. 24, j and k). d. All secondary batteries must be mounted on non-absorptive,...glass or thoroughly vitrified and glazed porcelain. e. The use of any metal liable to corrosion must be avoided in cell connections of secondary batteries.... | |
| Francis Bacon Crocker - 1901 - 528 стор.
...Special attention is directed to the rules for rooms where acid fumes exist (see No. 24, 7' and /•). d. All secondary batteries must be mounted on non-absorptive,...glass or thoroughly vitrified and glazed porcelain. e. The use of any metal liable to corrosion must be avoided in cell connections of secondary batteries.... | |
| Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...attention is directed to the rules for wiring in rooms where acid fumes exist (see No. 24 t and ;'). d. All secondary batteries must be mounted on non-absorptive,...glass or thoroughly vitrified and glazed porcelain. e. The use of any metal liable to corrosion must be avoided in cell connections of secondary batteries.... | |
| Saint Paul (Minn.). - 1908 - 1260 стор.
...thoroughly ventilated. c. Special attention is directed to the rules for rooms where acid, fumes exist. d. All secondary batteries must be mounted on non-absorptive,...glass, or thoroughly vitrified and glazed porcelain. e. The use of any metal liable to corrosion must be avoided in cell connections of secondary batteries.... | |
| Baltimore (Md.) - 1908 - 514 стор.
...apparatus fed from generators developing the same potential. PAR. 26. All secondary batteries shall be mounted on non-absorptive, non-combustible insulators,...glass or thoroughly vitrified and glazed porcelain. 1742 300 ELECTRICAL WORK. 301 1744 PAR 27. Transformers shall not be placed Transformers, inside of... | |
| Dallas (Tex.). - 1914 - 266 стор.
...attention is directed to the rules for wiring in rooms where acid fumes exist. (See Section 43n and o.) (d) All secondary batteries must be mounted on nonabsorptive,...glass or thoroughly vitrified and glazed porcelain. (e) The use of any metal liable to corrosion must be avoided in cell connections of storage batteries.... | |
| New York (State). Public Service Commission. First District - 1917 - 452 стор.
...as far as practicable, acid spray, so as to prevent dangerous accumulation of gas. (c) Cells shall be mounted on non-absorptive, non-combustible insulators,...glass or thoroughly vitrified and glazed porcelain. Edison storage cells are excepted. (d) Suitable drainage shall be provided to prevent the accumulation... | |
| New York (State). Public Service Commission. First District - 1918 - 792 стор.
...as far as practicable, acid spray, so as to prevent dangerous accumulation of gas. (c) Cells shall be mounted on non-absorptive, non-combustible insulators, such as glass or thoroughly vitrified aud glazed porcelain. Edison storage celia are excepted. (e) Storage battery rooms, it' lighted by... | |
| |